Chapter 2
Configuration and Installation
2-4
©
National Instruments Corporation
Figure 2-2 shows switch settings for logical addresses hex 5 and C0.
Figure 2-2.
Logical Address Selection
Hardware Installation
This section contains general installation instructions for the
VXI-AO-48XDC. Consult your VXIbus mainframe user manual or
technical reference manual for specific instructions and warnings.
1.
Plug in your mainframe before installing the VXI-AO-48XDC.
The power cord grounds the mainframe and protects it from
electrical damage while you are installing the module. Do
not
turn on the mainframe.
P1 Connector
U51
VXI-AO-48XDC Module
1 2 3 4 5 6 7 8
Logical Address
Switch
Push up for logic 1
Push down for logic 0
a. Switch Set to Logical Address Hex 5 (Default)
1 2 3 4 5 6 7 8
Logical Address
Switch
Push up for logic 1
Push down for logic 0
b. Switch Set to Logical Address Hex C0
LSB
MSB
MSB
LSB
P1 Connector
U51
VXI-AO-48XDC Module