Appendix A
Specifications
©
National Instruments Corporation
A-3
Digital logic levels
Bus Interface
Type ....................................................... Slave
Power Requirement
+5 V........................................................ 2 A
+12 V...................................................... 800 mA
–12 V...................................................... 800 mA
+24 V...................................................... 100 mA
–24 V...................................................... 100 mA
Note
These power usage figures do not include the power used by external devices that
are connected to the fused supply present on the I/O connector. They assume that
all voltage and current outputs are fully loaded.
Physical
Dimensions............................................. VXI C-size single slot
I/O connector.......................................... 96-pin (DIN x 2)
Level
Min
Max
Input low voltage
—
0.8 V
Input high voltage
2.0 V
—
Output low voltage
—
0.4 V, I
OL
= 12 mA
Output high voltage
2.4 V, I
OH
= 8 mA
—
Input leakage current
—
10 µA