RMX-4000 Series Programming Manual
85
Query Example
:MEAS:ALLV?
2.5000, 3.0000, 0.0000,
0.0000, 0.0000, 0.0000,
5.500, 0.0000
Channels 1 and 2 have
voltages of 2.5 V and
3 V, respectively.
Channels 3-6 and 8 have
no voltage, and channel
7 is 5.5 V.
85B
:MEASure:ALLCurrent?
All-Channel
Command
Description
This query returns the current measured of all the
load modules/channels in order from 1-8 (RMX-
4002)/1-4 (RMX-4000).
Query Syntax
:MEASure:ALLCurrent? <aard>
Query Parameter <aard> 1 unit = 1 A
CH1,CH2,CH3,CH4,CH5,
CH6,CH7,CH8
Returns all the current
values from all the
channels, 1-8 (RMX-
4002)/1-4 (RMX-4000).
Query Example
:MEAS:ALLC?
0.0000, 0.0000, 0.0000,
0.0000, 0.0000, 0.0000,
1.2000, 3.5600
Channels 1 to 6 have no
current. Channels 7 and
8 have 1.2 A and 3.56 A,
respectively.
86B
:MEASure:ALLPower?
All-Channel
Command
Description
This query returns the power measured of all the
load modules/channels in order from 1-8 (RMX-
4002)/1-4 (RMX-4000).
Query Syntax
:MEASure:ALLPower? <aard>
Query Parameter <aard> 1 unit = 1 W
CH1,CH2,CH3,CH4,CH5,
CH6,CH7,CH8
Returns all the power
values from all the
channels, 1-8 (RMX-
4002)/1-4 (RMX-4000).
Summary of Contents for RMX-400 Series
Page 31: ...RMX 4000 Series Programming Manual 31 0 Pass 1 Fail Example TST 0...
Page 56: ...RMX 4000 Series Programming Manual 56 Query Example UTIL FRAM 0 Frame Link is on...
Page 75: ...RMX 4000 Series Programming Manual 75 Syntax FETCh ALLPower aard...
Page 96: ...RMX 4000 Series Programming Manual 96 1 ON Turn on Example OCP RUN OFF Turn the test off...