RMX-4000 Series Programming Manual
114
125B
:RESistance:DYNamic:LOW:RISE/FALL
Channel-Specific
Command
Description
Sets the low range rising/falling slew rate for CR
dynamic mode for the specific channel.
Syntax
:RESistance:DYNamic:LOW:RISE/FALL <NRf+>[A/µs]
Parameter
<NRf+>[A/µs]
Slew rate
RISE/FALL 0.8A/µs
Sets the rising/falling slew
rate to 0.8 A/µs
RISE/FALL .1
Sets the rising/falling slew
rate to 0.1 A/µs
RISE/FALL MIN
Sets to the slowest
rising/falling slew rate
RISE/FALL MAX
Sets to the fastest
rising/falling slew rate
Example
:RES:DYNA:LOW:RISE 0.1
Sets the rising slew rate
to ~ 0.1 A/µs.
Query Syntax
:RESistance:DYNamic:LOW:RISE/FALL? [MIN|MAX]
Return Parameter <NR2> [MAX|MIN]
Slew rate
1 unit=1 A/µs
Returns the slew rate
MAX/MIN
Returns the allowable
maximum and minimum
Query Example
:RES:DYN:LOW:FALL?
MIN
0.8000
For low range dynamic
CR mode, the minimum
value for the falling slew
rate is 0.8 A/µs for the
specific channel.
126B
:RESistance:DYNamic:LOW:T1/T2
Channel-Specific
Command
Description
Sets the timers T1 or T2 for CR dynamic mode for
the specific channel in low range.
Syntax
:RESistance:DYNamic:LOW:T1/T2 <NRf+>[S|ms]
Summary of Contents for RMX-400 Series
Page 31: ...RMX 4000 Series Programming Manual 31 0 Pass 1 Fail Example TST 0...
Page 56: ...RMX 4000 Series Programming Manual 56 Query Example UTIL FRAM 0 Frame Link is on...
Page 75: ...RMX 4000 Series Programming Manual 75 Syntax FETCh ALLPower aard...
Page 96: ...RMX 4000 Series Programming Manual 96 1 ON Turn on Example OCP RUN OFF Turn the test off...