RMX-4000 Series Programming Manual
100
Description
Simulates short circuits for load channels for the
current sequence number.
Syntax
:PROGram:SEQuence:SHORt:CHANnel <NR1>
Parameter
<NR1>
(BIT WEIGHT)
Channel
number
<NR1>
(BIT WEIGHT)
Channel
number
1
1
16
5
2
2
32
6
4
3
64
7
8
4
128
8
Example
:PROG:SEQ:SHOR:CHAN
12
Simulates a short circuit
for channels 3 and 4.
Query Syntax
:PROGram:SEQuence:SHORt:CHANnel? <NR1>
Return Parameter <NR1>
(BIT WEIGHT)
Short
Channel
number
<NR1>
(BIT WEIGHT)
Short
Channel
number
1
1
16
5
2
2
32
6
4
3
64
7
8
4
128
8
Query Example
:PROG:SEQ:SHOR:CHAN?
12
Return channels 3 and 4
are set as shorted for
the program sequence.
107B
:PROGram:SEQuence:SHORt:TIME
Program Number
Specific
Description
Sets the short time (seconds) for the current
program sequence.
Syntax
:PROGram:SEQuence:SHORt:TIME <NRf>[S]
Parameter
<NRf>[S]
Short Time
0.0
0 s = OFF
0.1~60
0.1~60 s
Summary of Contents for RMX-400 Series
Page 31: ...RMX 4000 Series Programming Manual 31 0 Pass 1 Fail Example TST 0...
Page 56: ...RMX 4000 Series Programming Manual 56 Query Example UTIL FRAM 0 Frame Link is on...
Page 75: ...RMX 4000 Series Programming Manual 75 Syntax FETCh ALLPower aard...
Page 96: ...RMX 4000 Series Programming Manual 96 1 ON Turn on Example OCP RUN OFF Turn the test off...