![background image](http://html.mh-extra.com/html/national-instruments/pxie-3610/pxie-3610_getting-started-manual_3481823054.webp)
Figure 37. Interconnecting the Unidirectional MIMO (Baseband and IF) RX Chassis to
the Coding Chassis
NI PXIe-3620
IF-LO Module, 2 GHz BW
TX
LO1
IN
LO1
IF OUT
IF IN
IF SYNC IN
IF SYNC OUT
REF IN
REF OUT
LO2 OUT
ESD
SENSITIVE
LO2 IN
I+
I–
Q+
Q–
I+
I–
Q+
Q–
DIGITAL I/O
LVTTL
LO1
LO1
OUT
LO1
IN
LO1
OUT
RX
mmWave
PXIe-7902
CLK
IN
POR
T
2
POR
T
3
POR
T
4
POR
T
5
POR
T
0
POR
T
1
PXIe-3630
I/Q Digitizer
REF IN
+10 dBm
NOM
+13 dBm
MAX
1.5 Vp-p
DIFF MAX
1.5 Vp-p
DIFF MAX
0 Vcm
ALL PORTS 50
Ω
REF
OUT
0
1
2
3
Q+
Q–
I+
I–
ACCESS
ACTIVE
NI PXIe-3620
IF-LO Module, 2 GHz BW
TX
LO1
IN
LO1
IF OUT
IF IN
IF SYNC IN
IF SYNC OUT
REF IN
REF OUT
LO2 OUT
ESD
SENSITIVE
LO2 IN
I+
I–
Q+
Q–
I+
I–
Q+
Q–
DIGITAL I/O
LVTTL
LO1
LO1
OUT
LO1
IN
LO1
OUT
RX
mmWave
PXIe-7902
CLK
IN
POR
T
2
POR
T
3
POR
T
4
POR
T
5
POR
T
0
POR
T
1
PXIe-3630
I/Q Digitizer
REF IN
+10 dBm
NOM
+13 dBm
MAX
1.5 Vp-p
DIFF MAX
1.5 Vp-p
DIFF MAX
0 Vcm
ALL PORTS 50
Ω
REF
OUT
0
1
2
3
Q+
Q–
I+
I–
ACCESS
ACTIVE
2
1
3
4
5
6
7
8
9
11
12
13
14
15
16
17
18
10
NI PXIe-1085
10 MHz REF OUT
IN
24 GB/s
NI PXIe-8381
MXI-Express x8
PWR/LINK
Embedded Controller
RESET
TRIG
ACT/
LINK
ACT/
LINK
2
1
10/100
/1000
10/100
/1000
USER1
USER2
PWR OK/
FAULT
DRIVE
GPIB
2
1
3
4
5
6
7
8
9
11
12
13
14
15
16
17
18
10
NI PXIe-1085
10 MHz REF OUT
IN
24 GB/s
NI PXIe-7976R
NI FlexRIO
Kintex-7
410T
FPGA
2 GB
DRAM
NI PXIe-7976R
NI FlexRIO
Kintex-7
410T
FPGA
2 GB
DRAM
NI PXIe-7976R
NI FlexRIO
Kintex-7
410T
FPGA
2 GB
DRAM
NI PXIe-7976R
NI FlexRIO
Kintex-7
410T
FPGA
2 GB
DRAM
NI PXIe-7976R
NI FlexRIO
Kintex-7
410T
FPGA
2 GB
DRAM
NI PXIe-7976R
NI FlexRIO
Kintex-7
410T
FPGA
2 GB
DRAM
NI PXIe-7976R
NI FlexRIO
Kintex-7
410T
FPGA
2 GB
DRAM
NI PXIe-7976R
NI FlexRIO
Kintex-7
410T
FPGA
2 GB
DRAM
NI PXIe-7976R
NI FlexRIO
Kintex-7
410T
FPGA
2 GB
DRAM
NI PXIe-7976R
NI FlexRIO
Kintex-7
410T
FPGA
2 GB
DRAM
NI PXIe-7976R
NI FlexRIO
Kintex-7
410T
FPGA
2 GB
DRAM
NI PXIe-7976R
NI FlexRIO
Kintex-7
410T
FPGA
2 GB
DRAM
NI PXIe-8381
MXI-Express x8
PWR/LINK
PXIe-7902
CLK
IN
POR
T
2
POR
T
3
POR
T
4
POR
T
5
POR
T
0
POR
T
1
PXIe-7902
CLK
IN
POR
T
2
POR
T
3
POR
T
4
POR
T
5
POR
T
0
POR
T
1
5
4
7
1
2
3
6
1. PXIe-8381 Remote Control Module
2. Mini-SAS HD(m)-to-Mini-SAS HD(m) (8.25 in.)
Cables
3. MMPX(m)-to-MMPX(m) Cables
4. Mini-SAS HD(m)-to-Mini-SAS HD(m) (8.25 in.)
Cable
5. Mini-SAS HD(m)-to-Mini-SAS HD(m) (18 in.)
Cable
6. Mini-SAS HD(m)-to-Mini-SAS HD(m) (18 in.)
Cable
7. Mini-SAS HD(m)-to-Mini-SAS HD(m) (8.25 in.)
Cable
54
|
ni.com
|
mmWave Transceiver System Getting Started Guide