background image

Table 1. AC Power Cables

Power Cable

Reference Standards

 

 

Standard 120 V (USA)

ANSI C73.11/NEMA 5-15-P

Switzerland 220 V

SEV 6534-2

Australia 240 V

AS C112

Universal Euro 230 V

CEE (7), II, IV, VII

United Kingdom 230 V

BS 1363

Japan 100 V

JIS 8303

If you are missing any of the items, or if you have the incorrect AC power cable, contact
National Instruments

Key Features

The PXIe-1092 chassis combines a high-performance 9-slot PXI Express backplane with a
high-output power supply and a structural design that has been optimized for maximum
usability in a wide range of applications. The chassis’ modular design ensures a high level of
maintainability, resulting in a very low mean time to repair (MTTR). The PXIe-1092 chassis
fully complies with the 

PXI-5 PXI Express Hardware Specification

, offering advanced timing

and synchronization features.

An optional timing and synchronization upgrade provides inter-chassis trigger routing
capability, higher accuracy CLK10 and CLK100, connectors for 10 MHz reference clock input
and output, and remote chassis monitoring and inhibit control.

The key features of the PXIe-1092 chassis include the following:

High Performance for Instrumentation Requirements

Up to 8 GB/s (single direction) per PXI Express slot dedicated bandwidth (x8 Gen-3 PCI
Express).

58 W per slot cooling from 0 °C to 55 °C, and 82 W per slot cooling from 0 °C to 40 °C,
meets increased PXI Express cooling requirements

Low-jitter internal 10 MHz reference clock for PXI/PXI Express slots with ± 25 ppm
stability

Low-jitter internal 100 MHz reference clock for PXI Express slots with ± 25 ppm
stability

Quiet operation for 0 to 30 °C at 35.9 dBA

Variable speed fan controller optimizes cooling and acoustic emissions

Complies with PXI and CompactPCI Specifications

PXIe-1092 User Guide

  | 

© National Instruments

  | 

3

Summary of Contents for PXIe-1092

Page 1: ...heral Slots 7 System Timing Slot 8 Peripheral Expansion Slot 9 PXI Local Bus 10 PXI Trigger Bus 11 System Reference Clock 11 Installation and Configuration 12 Safety Information 13 Chassis Cooling Con...

Page 2: ...ed Unpacking Carefully inspect the shipping container and the chassis for damage Check for visible damage to the metal work Check to make sure all handles hardware and switches are undamaged Inspect t...

Page 3: ...d timing and synchronization features An optional timing and synchronization upgrade provides inter chassis trigger routing capability higher accuracy CLK10 and CLK100 connectors for 10 MHz reference...

Page 4: ...ronization across multiple chassis Switchless CLK10 routing Optional Features Timing and synchronization upgrade Front and rear rack mount kits Replacement power supply EMC filler panels Slot blockers...

Page 5: ...Express Hybrid Peripheral Slots 7x 6 PXI Express System Timing Slot 7 PXI Express System Controller Slot 8 Front Panel LEDs 9 Power Inhibit Switch 10 Chassis Carry Handle 11 DIP Switch Figure 2 Rear...

Page 6: ...Instruments that can accommodate a variety of rack depths PXIe 1092 Backplane Overview Interoperability with CompactPCI The design of the PXIe 1092 provides you the flexibility to use the following d...

Page 7: ...K10 PXI Star PXI Trigger Bus and PXI Local Bus 6 By default the system controller controls the power supply with the PS_ON signals A logic low on this line powers on the power supply Note The chassis...

Page 8: ...I Express peripheral or hybrid peripheral slot can link up to a Gen 3 x8 PCI Express providing a maximum nominal single direction bandwidth of 8 GB s A PXI Express Peripheral with x8 x4 or x1 PCI Expr...

Page 9: ...ipheral slots The peripheral expansion slot provides power and connectors for alignment but does not provide I O For more information about peripheral expansion slot connector pinouts refer to the Exp...

Page 10: ...ND NC NC NC GND 3 GND 12 V 12 V GND GND GND GND 4 GND GND GND 3 3 V 3 3 V 3 3 V GND 5 GND NC NC NC GND NC GND 6 GND NC GND NC NC NC GND 7 GND NC NC NC GND NC GND 8 GND NC GND NC NC NC GND PXI Local Bu...

Page 11: ...bridges through buffers This allows you to send trigger signals to and receive trigger signals from every slot in the chassis Static trigger routing user specified line and directional assignments can...

Page 12: ...slot PXI_CLK10 PXIe_CLK100 and PXIe_SYNC100 have the default timing relationship described in the following figure Figure 6 System Reference Clock Default Behavior PXIe_CLK100 PXI_CLK10 PXIe_SYNC100...

Page 13: ...nder such conditions this equipment is unsafe and may ignite the gases or gas fumes Part Replacement Only service this equipment with parts that are exact replacements both electrically and mechanical...

Page 14: ...ces may result in undesired thermal related issues with the chassis or modules To aid in thermal health monitoring for either rack or benchtop use you can monitor the chassis intake temperatures in Me...

Page 15: ...de Air Exhaust Vent Left Note The side exhaust vent not shown is located on the left side of the chassis Chassis Ambient Temperature Definition The chassis fan control system uses ambient intake air t...

Page 16: ...tive mounting screws provided Installing Slot Blockers The cooling performance of the chassis can be improved by installing optional slot blockers Refer to the National Instruments website at ni com i...

Page 17: ...If your power outlet does not have an appropriate ground connection you must connect the premise safety ground to the chassis grounding screw located on the rear panel To connect the safety ground com...

Page 18: ...er manual for specific instructions and warnings Caution Be sure the chassis is connected to an AC power source before installing the system controller The AC power cord grounds the chassis and protec...

Page 19: ...ller boots If the system controller does not boot refer to the Troubleshooting section or your system controller user manual Installing Peripheral Modules Caution The PXIe 1092 chassis has been design...

Page 20: ...ctor Handle 2 PXI Peripheral Module 3 Peripheral Module Front Panel Mounting Screws 2x 4 PXIe 1092 Chassis 5 Injector Ejector Rail 6 When you begin to feel resistance push up on the injector ejector h...

Page 21: ...n for the slot descriptions 6 Install the module in the chassis by aligning the module so that the right most portion of the multiple slot peripheral module will occupy the slot peripheral expansion s...

Page 22: ...y Steady red The chassis power supply has failed Temperature LED Off Chassis is powered off Steady green Intake or exhaust temperature is within chassis operating range Steady red Intake or exhaust te...

Page 23: ...tes Location Switch State Description 1 FAN Off Right Sets chassis Fan Mode to Auto On Left Sets chassis Fan Mode to High 2 PWR Off Right Sets chassis Inhibit Mode to Default On Left Sets chassis Inhi...

Page 24: ...o mode for improved acoustic performance In High mode the speed of the chassis fans is fixed at high speed regardless of chassis intake air temperature Select High mode for maximum cooling performance...

Page 25: ...ith your system controller PXI Platform Services creates the pxiesys ini and pxisys ini file which define your PXI system parameters Note The configuration steps for single or multiple chassis systems...

Page 26: ...er program Dynamic reservation routing deallocation is on the fly within a user program based on National Instruments APIs such as NI DAQmx NI recommends dynamic reservations and routing are used when...

Page 27: ...serve and route trigger lines for you so you won t have to route trigger lines manually Complete the following steps to configure trigger routings in MAX 1 In the Configuration tree select the chassis...

Page 28: ...tation for the PXIe 1092 chassis is contained in the chassis ini file on the software media that comes with the chassis The information in this file is combined with information about the system contr...

Page 29: ...odules Caution Always disconnect the power cable prior to servicing the chassis Interior Cleaning Use a dry low velocity stream of air to clean the interior of the chassis Use a soft bristle brush for...

Page 30: ...the screw locations Using a Phillips screwdriver remove the screws Pull on the rear handle of the power supply to remove it from the back of the chassis C O O L IN G C L E A R A N C E S R E Q U IR E...

Page 31: ...ear chassis feet 3 With the internal fan harness still connected carefully pull and rotate fan assembly from rear cavity of chassis Use caution when removing the fan assembly to avoid damaging the fan...

Page 32: ...Module 2 5 3 4 1 1 Fan Harness Plug 2 PXI Express Chassis 3 PXI Module Fan Assembly 4 Rear Chassis Feet 2x 5 Mounting Screws 6x Figure 18 Internal Fan Harness 1 2 1 Fan Receptacle 2 Fan Harness Plug 3...

Page 33: ...void damaging the internal wire harness 5 Pull side fan assembly straight from chassis and remove Installing the Side Fan Assembly Complete the following steps to install a new side fan assembly 1 Plu...

Page 34: ...ppropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents You can find information about end user license agreeme...

Reviews: