appears with an X and a reserved device appears as dark grey. Only one user at a time can
reserve the FieldDAQ device.
If the device was not reserved automatically after it was added (
Add Device
), you can reserve
the device in MAX by expanding
Devices and Interfaces
»
Network Devices
, selecting the
device, and clicking the
Reserve Network Device
button. The Override Reservation dialog
box opens when you attempt to explicitly reserve a device. Agreeing to override the
reservation forces the FieldDAQ device to be reserved by the current user.
STATUS LED
The FieldDAQ device has a STATUS LED.
Table 10. LED State/Device Status
LED Color and
State
Device Status
Off
Device is reserved by NI-DAQmx, but there is no activity, the device
is not powered, or the device is not reserved by NI-DAQmx.
Yellow, solid
Device firmware is booting or updating.
Red, blinking
Device has reset to factory default or the firmware image is corrupted.
If you are not performing a factory default reset, as listed in
Resetting
the FieldDAQ to Factory-Default Settings
, contact NI for support on
corrupted firmware.
Green, solid
Device is reserved and a DAQ task is running.
Resetting the FieldDAQ to Factory-Default
Settings
To reset your FieldDAQ device to factory-default settings, complete the following steps.
1.
Verify the power source is turned off.
2.
Connect Ethernet port 0 and port 1 with an Ethernet cable.
Figure 20. Connecting Port 0 and Port 1
0
10/100/1000
SYNC
1
LINK/ACT
30
|