5-28
|
ni.com
Chapter 5
Counters
Continuous pulse train generation is sometimes called frequency division. If the high and low
pulse widths of the output signal are
M
and
N
periods, then the frequency of the Counter
n
Internal Output signal is equal to the frequency of the Source input divided by
M
+
N
.
For information about connecting counter signals, refer to the
section.
Buffered Pulse Train Generation
The cDAQ controller counters can use the FIFO to perform a buffered pulse train generation.
This pulse train can use implicit timing or sample clock timing. When using implicit timing, the
pulse idle time and active time changes with each sample you write. With sample clocked
timing, each sample you write updates the idle time and active time of your generation on each
sample clock edge. Idle time and active time can also be defined in terms of frequency and duty
cycle or idle ticks and active ticks.
Note
On buffered implicit pulse trains the pulse specifications in the DAQmx
Create Counter Output Channel are ignored so that you generate the number of pulses
defined in the multipoint write. On buffered sample clock pulse trains the pulse
specifications in the DAQmx Create Counter Output Channel are generated after the
counters starts and before the first sample clock so that you generate the number of
updates defined in the multipoint write.
Finite Implicit Buffered Pulse Train Generation
This function generates a predetermined number of pulses with variable idle and active times.
Each point you write generates a single pulse. The number of pairs of idle and active times (pulse
specifications) you write determines the number of pulses generated. All points are generated
back to back to create a user defined pulse train.
Table 5-6 and Figure 5-32 detail a finite implicit generation of three samples.
Table 5-6.
Finite Implicit Buffered Pulse Train Generation
Sample
Idle Ticks
Active Ticks
1
2
2
2
3
4
3
2
2