![National Flooring Equipment PANTHER 8274 Instruction Manual Download Page 22](http://html1.mh-extra.com/html/national-flooring-equipment/panther-8274/panther-8274_instruction-manual_708544022.webp)
Page 22
For any other problems or questions, please contact NATIONAL at 1-800-245-0267
8274/9274 PROCEDURE
Trouble
Possible Cause
Remedy
Overload Run
Motor overloaded
Remove weight, slow machine
or change tooling
Low Volts Acceleration
Line volts too low at start
a. Check cord length and
gauge
b. Check power source
Low Volts Run
Line volts too low
a. Check cord length and
gauge
b. Check power source
High Voltage
Line volts too high
Wired wrong or to improper
supply
Power Sag
Erratic line volts
Check power supply, cord or
for loose connection
External Acceleration
Kill switch off
Check kill switch - it is either
off or malfunctioning
External Run
Kill switch off
Check kill switch - it is either
off or malfunctioning
CONTROLLER CODES
8274-1 & 9274-1
Description
First Flash
Second Flash
Third Flash
Over Temp
Dot
Dot
Dot
Thermal Switch
Dot
Dot
Dash
Hall Error
Dot
Dash
Dot
Over Current
Dot
Dash
Dash
Under Voltage
Dash
Dot
Dot
Over Voltage
Dash
Dot
Dash
Enable at Power
Dash
Dash
Dot
No Motion
Dash
Dash
Dash
8274-4 & 9274-2
C
ONTROLLER
E
RROR
C
ODES
Error codes are a binary flashing sequence of the Fault LED (and fault I/O line)
C
ONTROLLER
D
EFAULT
C
ODES