MANUAL OF
USE AND MAINTENANCE
ATLANTIC 100
P g .
|
3
ATLANTIC 100 - Rev.00/16 Cod. AT200-002
1. Filling hose with monometer and valve
2. Electrical motor (or internal combustion engine)
3. Tubular frame
4. Cooling fan
5. Air conveyor
6. Condensate release valves
7. Maximum pressure safety valve
8. Intake filter
9. Vibration damping feet
4. TECHNICAL DATA
Compressor Model
ATLANTIC 100
Operating pressure
PN 200
PN 300
Air output
100 L/min. (± 5%)
100 L/min. (± 5%)
Safety valve max. pressure
225 Bar
330 Bar
Pumping Group
ATLANTIC 100
Number of stages
4
Intermediate pressure 1
st
stage
2.5 Bar
Intermediate pressure 2
nd
stage
15 Bar
Intermediate pressure 3
rd
stage
55 - 65 Bar
Intermediate pressure 4
th
stage
225 - 330 Bar
Oil sump capacity
0.350 Litres
Oil Type
SHELL CORENA P150
Ambient temperature operating limits
-5°C Min. +45°C Max. (+25°F Min. +113°F Max.)
Max. permitted inclination
10°
Max. air humidity
80%
Max. altitude above sea level
2000 m a.s.l.
Electrical motor
Single phase
Three phase
Type of current
230 Volt / 50–60 Hz
230-400-440 Volt / 50-60 Hz
Electrical motor power
3.0 Hp 2 poles
4 Hp 2 poles
Protection
IP 54
IP 54
Absorption
15 A
11.4 - 6.6 A
Internal Combustion Engine
ROBIN EX17 6.0 Hp 4 STROKE
Start up
MANUAL PULL START
Cylinder capacity
169 ml.
Internal combustion engine power
4.4 Kw-6.00 HP / 3900 r.p.m.