W415-2899 / A / 10.07.20
EN
20
installation
1.0 Place the standoff in the framed
opening, using the tabs as guides.
2.0 Secure the standoff to the
sheathing using the 8 long screws
(supplied in standoff kit). The
screws should penetrate through
the sheathing and into the wall
framing.
7.1 vinyl siding - between 1” (25mm) and 2” (51mm) (all)
3.0 Attach the termination to the venting,
see “pre-installation” and “venting”
sections.
note:
Diagrams are for illustrative
purposes only. Installation must
comply with all local codes.
Refer to “venting requirements” and “venting installation” sections in
your appliance installation manual.
Silicone
Silicone
Terminal
X 4
• Terminal (ST47U)
• Brick Standoff (SOST47B)
Required for 4”7”:
• Terminal (ST58U-1)
• Brick Standoff (SOST58B)
Required for 5”/8”:
note:
All inner flex pipe and outer flex pipe
joints to the termination may be sealed
using high temperature red RTV silicone
W573-0002 (not supplied) or the high
temperature sealant W573-0007 Mill
Pac (not supplied). However, the high
temperature sealant W573-0007 Mill
Pac (not supplied) must be used on the
joint connecting the inner flex pipe and
the exhaust flue collar of the appliance.
4.0 Install the termination and venting
from the outside of the building,
bringing the venting through the
opening in the wall.
5.0 Slide the terminal return flange over
the standoff and secure with 4 short
screws (supplied in standoff kit).
6.0 Apply a bead of clear silicone to seal
the edges of the termination.
7.0 Apply the vinyl siding around the
brick standoff and termination,
sealing between the termination and
vinyl siding (1” [25mm] - 2” [51mm])
with silicone.
X 8
Brick Standoff