EN
W415-2899 / A / 10.07.20
3
general information
* Where applicable, an additional standoff or brick standoff kit is required. These applications may result in the
terminal flange being proud of the finish material.
For applications where the terminal is situated in an accessible location, an additional terminal guard
kit must be installed. See “terminal guard installation (all)” section for complete details.
All installations must comply with local and national codes.
For 4” / 7” appliances:
Vinyl siding and Exterior finish material (less than
1” thick (25mm):
No additional standoff kit is required for applications
with 1” (25mm) or thinner finish material (including
vinyl).
See “vinyl siding - less than 1” (25mm) (4”/7” only)”
or “exterior finish material less than 1” (25mm) (all)”
sections.
Vinyl siding between 1” (25mm) and 2” (51mm):
An additional brick standoff kit is required.
See “vinyl siding - between 1” (25mm) and 2” (51mm)
(all)” section.
Exterior finish material between 1” (25mm) and 2”
(51mm):
An additional standoff kit is required.
See “exterior finish material - between 1” (25mm) and
2” (51mm) (all)” section.
Brick:
An additional brick standoff kit is required.
See “brick (all)” section.
1.1 installation overview
For 5” / 8” appliances:
Vinyl siding (less than 1” thick (25mm):
An additional standoff kit is required for applications
with vinyl siding less than 1” (25mm).
See “vinyl siding - less than 1” (25mm) (5”/8” only)”
section.
Vinyl siding between 1” (25mm) and 2” (51mm):
An additional brick standoff kit is required.
See “vinyl siding - between 1” (25mm) and 2” (51mm)
(all)” section.
Exterior finish material (less than 1” thick (25mm):
No additional standoff kit is required for applications
with 1” (25mm) or thinner finish material (excluding
vinyl).
See “exterior finish material - less than 1” (25mm) (all)”
section.
Exterior finish material between 1” (25mm) and 2”
(51mm):
An additional standoff kit is required.
See “exterior finish material - between 1” (25mm) and
2” (51mm) (all)” section.
Brick:
An additional brick standoff kit is required.
See “brick (all)” section.
1.0 general information
!
WARNING
• FIRE HAZARD! Failure to comply with these installation instructions could result in serious damage.
• Do
NOT
finish past the terminal
return flange
.
RISK OF FIRE!
Under no
circumstance
can
ANY
finish
material or
surface ever
extend
past
the
terminal return
flange.*
IMPOR
TANT
Return
flange
Finish
material
or
surface
Return
flange
Finish
material
or
surface
Return
flange
Finish
material
or
surface