W415-2837 / 08.11.20
EN
28
operation
6.1 optimum burn method
For optimal emissions performance and efficiency follow these simple guidelines when using your
appliance:
A.
Maintain a 2" (51mm) deep, hot, glowing red coal bed.
B.
Burn dry seasoned wood with less than 20% moisture content and burn so that the glass door remains
clean.
C.
A stove thermometer 18" (457mm) up on the single wall stove pipe should indicate 350°F (176°C) as an
average temperature.
D.
Maintain a minimal trace of smoke coming from the chimney when the appliance is burning as intended.
E.
Inspect and replace all necessary components such as gaskets, manifolds, glass and other components
which may affect the overall appliance performance.
F.
Ensure an adequate draft to control burn rate and temperature.
Refer to “operation” and “maintenance” sections for detailed information.
6.2 optional blower operation
The following operating procedure is recommended to achieve optimal performance:
When operating on high burn rate:
1.
We recommend setting the blower to the “HIGH” setting and operating with a thermodisc (located at the
back of the appliance).
When operating on medium burn rate:
2.
We do not recommend using the blower.
When operating on low burn rate:
3.
We recommend turning on the blower after approximately 60 minutes at the minimum setting and
operating with a thermodisc (located at the back of the appliance).