installation planning
2.4 minimum clearance to combustibles
!
WARNING
• Do not install into any area having less than 7 feet (2.1m) (ceiling to appliance bottom, excluding hearth height).
CONFIGURATION
SIDE WALL
(A)
SIDE WALL
TO FLUE
(B)
BACK
WALL (C)
BACK
WALL TO
FLUE (D)
CEILING
(E)
With T
.H.S.
Straight with single wall pipe
16 1/4”
(41.2cm)
27 1/2”
(69.8cm)
9 1/2”
(24.1cm)
11”
(27.9cm)
84”
(213.3cm)
Straight with double wall pipe
6 1/2”
(16.5cm)
7 1/2”
(19cm)
Through the wall with single wall pipe
9 1/2”
(24.1cm)
11”
(27.9cm)
Through the wall with double wall pipe
6 1/2”
(16.5cm)
7 1/2”
(19cm)
Without T
.H.S.
Straight with single wall pipe
*
16 1/4”
(41.2cm)
27 1/2”
(69.8cm)
14 1/2”
(36.8cm)
16”
(40.6cm)
96”
(243.8cm)
Straight with double wall pipe
*
12 1/2”
(31.7cm)
13 1/2”
(34.2cm)
Through the wall with single wall pipe
*
14 1/2”
(36.8cm)
16”
(40.6cm)
Through the wall with double wall pipe
*
12 1/2”
(31.7cm)
13 1/2”
(34.2cm)
CONFIGURATION
SIDE WALL SIDE WALL
TO FLUE
BACK
WALL
BACK
WALL TO
FLUE
CEILING
With T.H.S.
Corner
(F)
4”
(10.1cm)
14 1/4”
(36.1cm)
4”
(10.1cm)
14 1/4”
(36.1cm)
84”
(213.3cm)
Without T
.H.S.
Corner
(F)
*
6”
(15.2cm)
16 1/4”
(41.3cm)
6”
(15.2cm)
16 1/4”
(41.2cm)
96”
(243.8cm)
BACK WALL
B
SI
D
E
W
A
LL
A
BACK WALL
C
SI
D
E
W
A
LL
F
K
J
J
I
D
E
E
BACK WALL
B
SI
D
E
W
A
LL
A
BACK WALL
C
SI
D
E
W
A
LL
F
K
J
J
I
D
E
E
E
BACK WALL
B
SI
D
E
W
A
LL
A
BACK WALL
C
SI
D
E
W
A
LL
F
K
J
J
I
D
E
E
F
F
Clearances can be reduced with shielding acceptable to
local authorities. Reduced installation must comply with
NFPA 211 or CAN/CSA-B365.
* The top heat shield (T.H.S) may be removed if desired
(Fig. 2-3)
; however, this will increase clearances to
combustibles.
Please read the above table carefully.