W415-1013 / C / 11.19.13
7
EN
2.3 GENERAL
INFORMATION
2.3.1 FEATURES
2.3.2 HEATING SPECIFICATIONS
IMPORTANT
Differences in chimney height and draft may lower overall burn times.
Approximate Heating Capacity up to 2,000 square feet (167.23m
2
) for HMF150 and 3,000 square feet
(278.71m
2
) for HMF200 (Will vary with the home's
fl
oor plan, insulation and outside temperature).
Maximum burn time up to 12 hours (HMF150), 18 hours (HMF200).
Average BTU Output per hour 70,000 - 85,000 (HMF150), 95,000 - 110,000 (HMF200).
Oil furnace module up to 91,000 BTU input.
Electric furnace up to 20 Kw (HMF150), 25 Kw (HMF200).
2.3.3 ELECTRICAL SPECIFICATIONS
Fully con
fi
gured furnace 13.3 amps, 120 V, when Riello oil burner is used in multi furnace con
fi
guration.
Fully con
fi
gured furnace 17.4 amps, 120 V, when Beckett oil burner is used in multifurnace con
fi
guration.
(Optional electric furnace module’s up to 85 amps.)
2.3.4 OPTIONAL MODULES
• Maximum log length of 24" (610mm) (HMF150),
and 30” (762mm) (HMF200)
• Long burn time - up to 12 hours (HMF150), 18
hours (HMF200)
• Automatic control with thermostat
• Large
fi
rebox capacity
• Outside air for combustion
• Choice of glass door for radiant heat through front
of furnace, or solid door to provide more heating
through exchange surfaces
• Firebrick lining for
fi
rebox creates kiln like tempera-
tures for maximum ef
fi
ciency and low emissions
2.3.5 APPLICABLE STANDARDS
2.3.6 CALIFORNIA PROP65
Use of this product may produce smoke which contains chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
Rating plate is located on furnace side panel without the return air opening.
2.4 RATING PLATE INFORMATION
Optional
Modules
Available:
• Glass Door HMFK-GLASS, Solid Door HMFK-SOLID
• “Add On” Furnace Module HMFK-ADDON
• Blower Box Module HMFK-BMP50-1
• HMF/Gas Transition Module HMFK-GT
• Electric Furnace Module HMFK-EF15, -EF18, - EF20 (HMF150), HMFK-EF18, -EF20, -EF25 (HMF200)
• Oil Furnace Module HMFK-CMBCH-1 (HMF150), HMFK-CCH200 (HMF200), HMFK-OFRF40,
HMFK-OFBNX, HMFK-WMO
• Bi Energy Module (Quebec) HMFK-BIEK
Certi
fi
cation Standards and Installation Codes:
UL391
UL727
CSA B366.1-M91
CSA B140.4-04
CSA B212-00
CSA B415.1-10
CSA B365-10
CSA B139-09
NFPA 211
CSA 22.1
CAN/CSA-C22.2 NO.0-M91
CAN/CSA-C22.2 NO.3-M1986
ANSI/NF NO.70
H3.31
DO NOT LET THE APPLIANCE BECOME HOT ENOUGH FOR ANY PART TO GLOW RED.