INSTALLATEUR : CETTE NOTICE DOIT ÊTRE REMISE AU PROPRIÉTAIRE DU POÊLE ET CONSERVÉE PAR LUI.

HOMOLOGUÉ SELON LES NORMES DE L’AGENCE DE PROTECTION DE L’ENVIRONNEMENT AMÉRICAINE (E.P.A.) JUILLET 1990 ET LE DÉPARTEMENT D’OREGON

DE LA QUALITÉ DE L’ENVIRONNEMENT (D.E.Q.) LES NORMES D’ÉMISSION DE PARTICULES DE E.E.M.C. CE POÊLE A ÉTÉ TESTÉ ET HOMOLOGUÉ PAR WARNOCK

HERSEY LTÉE SELON LES NORMES UL 1482 / ULC-S627.

LE MODÈLE 1600C-1 A ÉTÉ TESTÉ ET HOMOLOGUÉ POUR INSTALLATION LES MAISONS MOBILES.

INSTRUCTIONS D’INSTALLATION ET D’OPÉRATION POUR LES

APPAREILS DE CHAUFFAGE LOCALISÉ À COMBUSTIBLE SOLIDE

MODÈLE :

1600C-1

ATTENTION :

Veuillez lire le manuel d’instructions en entier avant d’installer et d’utiliser votre appareil de chauffage.

Si ces instructions ne sont pas suivies à la lettre, des dommages matériels, des blessures corporelles

ou des pertes de vie pourraient s’ensuivre.

Si cet appareil n’est pas installé adéquatement, un incendie pourrait en résulter.

POUR VOTRE SÉCURITÉ :

Observez les instructions d’installation. Ce poêle peut devenir très chaud pendant la chauffe. Les matériaux

combustibles tels que le bois de chauffage, les vêtements détrempés etc., placés trop près de l’appareil peuvent

prendre feu. Il faut empêcher les enfants et les animaux domestiques de toucher l’appareil lorsqu’il est chaud. La

cheminée doit être en bonne condition et doit être hermétique. Avant d’installer cet appareil, contactez le service du

bâtiment ou le service d’incendie de votre municipalité et suivez leurs directives.

Ne faites fonctionner l’appareil qu’avec la porte hermétiquement fermée. Vous devez garder la porte fermée durant

le fonctionnement pour éviter que la fumée et les braises s’infiltrent dans la pièce. Brûlez le bois directement sur le

chenet en fonte fourni avec l’appareil. Ne surélevez pas le feu. Au moins 14” carrés (90 cm ca.) d’air extérieur doit

être admis dans la pièce. Cet appareil est conçu pour brûler le bois à son état naturel seulement. Comparativement

aux bois mous ou aux bois verts fraîchement coupés, les bois durs et secs produiront des taux d’efficacité plus

élevés et des taux d’émissions plus bas. N’allumez pas l’appareil avec des produits chimiques ou des fluides tels

que de l’essence, de l’huile à moteur etc. Ne brûlez pas de bois traités, du charbon, du charbon de bois, du papier

couleur, du carton, des solvants ou des déchets qui ont tendances à produire plus de pollution que le bois. Ne

laissez pas chauffer l’appareil au point où ses composants seront chauffés au rouge.

GARDEZ LA TEMPERATURE SUR LE DESSUS DE L’APPAREIL SOUS 700°F (371°C). Toute tentative de

dépasser le débit maximum de chaleur tel que mentionné dans les spécifications du design des poêles, pourrait

provoquer la distorsion de l’acier et causer des dommages.

Wolf Steel Ltd., 24 Napoleon Rd.,

Barrie, ON., Canada L4M 4Y8 (705)721-1212

Fax : (705)722-6031

www.napoleonfireplaces.com

Email : [email protected]

Document

n°1

178-1

~

02/12/2004

Summary of Contents for 1600C-1

Page 1: ...nd free of cracks Before installing this unit contact the local building or fire authority and follow their guidelines Operate only with door tightly closed The door must be kept closed during operati...

Page 2: ...ng on porcelain enamel parts nor any venting components used in the installation of the fireplace In the first year only this warranty extends to the repair or replacement of warranted parts which are...

Page 3: ...eration p 4 Care of glass p 4 INSTALLATION p 5 Alcove installation p 6 Stove installation p 6 INSTALLATION WHEN INSTALLED WITH BLOWER KIT EP63 p 6 Adding chimney sections p 7 Outside air p 7 Flue coll...

Page 4: ...n or a warm weather season the fireplace may emit a slight odour for a few hours This is caused by dust particles in the firebox burning off Open a window to sufficiently ventilate the room If the out...

Page 5: ...that extends 8 200mm beyond the stove sides and back and 18 455mm to the front Listed single wall chimney connector Flue configuration Type 1 Horizontal Vertical FROM UNIT A 16 16 B 22 22 C 15 15 FRO...

Page 6: ...ond the stove sides and back and 18 455mm to the front Listed single wall chimney connector Flue configuration Type 1 Horizontal Vertical FROM UNIT A 16 16 B 10 16 C 11 11 FROM PIPE D 25 25 E 18 F 18...

Page 7: ...oist for extra support Firestop spacers must be placed on the bottom of each framed opening in any floor or ceiling that the chimney passes through 3 Hold a plumb bob from the underside of the roof to...

Page 8: ...the outside as well as securing the unit to the floor is mandatory in mobile homes only Use a fresh air kit and the floor securing brackets Avoid cutting away floor joists wall studs electrical wires...

Page 9: ...larger again as soon as the castings have been heated thoroughly and the chimney becomes heated and provides a good draft At this point the roaring fire that you see when the door is opened is wastefu...

Page 10: ...e 4 screws removed and secure to the 4 spacers The flue collar shield is only needed if the flue collar is in the top exit position If the flue collar is in the rear exit position the flue collar shie...

Page 11: ...room too airtight Try with a window partly open Is the smoke flow impeded by too long a horizontal pipe or too many bends Is it a weak draft perhaps caused by a leaky chimney a cold outside chimney to...

Page 12: ...plate P N F 01 12 105275 Ceramic brick liner P N F 01 13 306285 EF Back panel P N F 01 14 331001 EF Adaptor P N F 01 15 303826 EF Flue collar P N F 01 16 157968 Rating plate P N F 01 17 310734 RJ Rig...

Page 13: ...1900 EF Door left side P 01 40 331900 77 Door left side N 01 41 110404 Hinge pin 6X30 door P N F 04 42 181632 Gasket door glass P N F 2 m 43 188829 Ceramic glass 278 X 220 P N F 02 44 259015 00 Bracke...

Page 14: ...14...

Page 15: ...ue Avant d installer cet appareil contactez le service du b timent ou le service d incendie de votre municipalit et suivez leurs directives Ne faites fonctionner l appareil qu avec la porte herm tique...

Page 16: ...n caus s par une chaleur excessive des produits d entretien chimiques et abrasifs ou l caillage des pi ces en mail de porcelaine ou tout composant de ventilation utilis dans l installation du po le Au...

Page 17: ...s une alc ve p 5 Installation du po le p 5 INSTALLATION AVEC LE KIT SOUFFLERIE EP63 p 6 Ajout de sections de chemin e p 7 Air ext rieur p 7 Inversion du collet de conduit d vacuation p 7 Installation...

Page 18: ...e il se peut qu une l g re odeur s en d gage pendant quelques heures Ceci est caus par des particules de poussi re br lant dans le po le Ouvrez une fen tre afin d a rer la pi ce de mani re suffisante...

Page 19: ...er de 457 mm sur le devant Raccord simple paroi Flue configuration Type 1 Horizontal Vertical DU PO LE A 406 mm 406 mm B 559 mm 559 mm C 381 mm 381 mm DU CONDUIT D 635 mm 635 mm E 559 mm Une distance...

Page 20: ...ccord simple paroi Flue configuration Type 1 Horizontal Vertical DU PO LE A 406 mm 406 mm B 254 mm 406 mm C 280 mm 280 mm DU CONDUIT D 635 mm 635 mm E 457 mm F 457 mm Une distance minimum de 457 mm se...

Page 21: ...s par la chemin e les espaceurs coupe feu doivent tre fix s la base de la charpente de l ouverture 3 D terminez les dimensions de l ouverture d couper dans le toit l aide d un fil plomb Dessinez l ouv...

Page 22: ...n au plancher n est obligatoire que pour les maisons mobiles Utilisez un ensemble de prise d air ext rieur et des supports de fixation pour plancher vitez de sectionner les solives de plancher les mon...

Page 23: ...s efficaces Les flammes resteront paresseuses mais plus grandes d s que le po le sera compl tement chaud et que la chemin e soit chaude et fournisse un bon tirage Le feu grondant que vous voyez quand...

Page 24: ...par les 4 entretoises fournies Installez l cran arri re en utilisant les 4 vis retirez et le fixer sur les 4 entretoises L cran de buse n est n cessaire quand cas de raccordement vertical Lors d un ra...

Page 25: ...que le flot de fum e est restreint par un tuyau vertical trop long ou par un trop grand nombre de coudes S agit il d un tirage faible caus par une chemin e non herm tique une chemin e ext rieure froid...

Page 26: ...F 01 11 330018 EF Plaque motif P N F 01 12 105275 Brique d isolation c ramique P N F 01 13 306285 EF Derri re P N F 01 14 331001 EF Adaptateur P N F 01 15 303826 EF Buse P N F 01 16 157968 Plaque sign...

Page 27: ...01 41 110404 Clou cannel 6X30 P N F 04 42 181632 Tresse c ramique DIAM 6 P N F 2 m 43 188829 Verre n oc ramique 278 X 220 P N F 02 44 259015 00 Patte fixation P N F 08 45 142881 Joint P N F 08 46 8080...

Page 28: ...14...

Reviews: