7
AR M I N G AW AY : S E T T I N G T H E AL AR M W H E N L E AV I N G
BYPASS
P L E A S E E X I T
0 4 0 S E C O N D S
SYS TBL
S Y S T E M T R O U B L E
L O W B A T T E R Y
SYS TBL
C A N ’ T A R M S Y S T E M
. . . P R E S S R E S E T
C A N ’ T A R M S Y S T E M
. . . Z O N E F A U L T E D
0 2 B A C K D O O R
Selectively Bypassing Zones
If you cannot locate or repair the problem yourself, call for assistance. If you
cannot get immediate help, bypass the problem zone(s) from the system by
pressing
B
, then the single-digit zone number. The word BYPASS appears on
the display. (You can “un-bypass” the bypassed zone by pressing
B
and the
zone number again). With the zone(s) bypassed, arm the system (enter your code
and press
Q
), and leave the premises.
Note:
Bypassed zones are unprotected. Therefore, if armed with zones bypassed,
be sure to have the system checked as soon as possible.
System Trouble
If you attempt to arm with a “SYSTEM TROUBLE” display along with an indicated
trouble message (e.g. “LOW BATTERY”; see SYSTEM TROUBLES), the window
will display “CAN'T ARM SYSTEM...PRESS RESET”. If you cannot correct the
problem immediately, press
C
to arm in this condition. Be sure to call for service
as soon as possible.