background image

 

OPERATING GUIDE for your 

 

GEM-DXRP3 KEYPAD 

© NAPCO 2007 

OI324A  1/07 

Summary of Contents for GEM-DXRP3

Page 1: ...1 OPERATING GUIDE for your GEM DXRP3 KEYPAD NAPCO 2007 OI324A 1 07 ...

Page 2: ...ustry standards To assure optimum safety and security familiarize yourself with this equipment Periodically check its condition and state of readiness by testing it at least once a week in both the ac battery and battery only modes ask your alarm professional how to make these tests INTRODUCTION Test your sounding device and backup battery 1 While disarmed press w 2 Answer X press z until 3 Bell T...

Page 3: ...ES 21 PROGRAMMING USER CODES 22 GLOSSARY 24 SYSTEM TROUBLE ERROR CODES 27 TROUBLESHOOTING 31 TO SILENCE AN ALARM ENTER YOUR CODE AND PRESS v FOR SERVICE CALL __________________ CENTRAL STATION __________________ EXIT DELAY _________________________ ENTRY DELAY ______________________ FIRE ALARM SOUND ________________________________ BURGLAR ALARM SOUND ________________________________ KEYPAD FIRE E...

Page 4: ...4 KEYPAD CONTROLS INDICATORS w 1 2 3 x 4 5 6 y 7 8 9 0 p z G v ARMED STATUS 2 3 4 5 6 7 8 9 10 11 12 r x INTERIOR BYPASS FIRE TBL SYS TBL CHIME 96 1 13 ...

Page 5: ...1 Resets various system troubles displays etc see text 2 Resets residential smoke detectors Numerical Keys 1 9 0 Used to enter codes zone numbers etc ON OFF v Button Entry key Causes the entered code or selected function to be executed INTERIOR p Button 1 Bypasses all Interior Zones simultaneously to allow free movement within the premises 2 Scrolls the window display forward NEXT 3 Answers YES to...

Page 6: ...ve the premises Leave through the exit door before the exit time expires Priority Arming If you attempt to arm the system with a faulted Zone a 3 second tone will sound at the keypad and P will display in the window indicating that the zones must be secured before the panel can be armed Selectively Bypassing Zones If you cannot locate or repair a faulted zone it can be removed from the system or b...

Page 7: ...ers remain disarmed Manager s Mode The Manager s Mode allows the user to arm disarm other areas in a partitioned system To arm a different area 1 Press the numerical key representing the other area number 2 Press G followed by v The keypad will now provide status and control of that area 3 Enter your code followed by v to arm 4 Press G followed by v to return to the home area Global Arming Optiona...

Page 8: ...or Bypass which allows it to recognize that you have armed the system and remained in the house prompting it to automatically adjust the interior protection accordingly If you arm the system and remain in the house all Interior Zones are automatically bypassed The INTERIOR and or BYPASS lights which will remain lit indicating that it is safe to move about If the system is armed and you leave the I...

Page 9: ... Emergency programmed YES NO Easy Exit Optional Easy Exit programmed YES NO Your system may have been programmed for Easy Exit which allows a user to exit the premises while the system is armed By activating Easy Exit while the system is armed the Exit Delay countdown will take place during which time you are permitted to leave through the exit door The Easy Exit Delay time will be identical to th...

Page 10: ... call authorities from a neighbor s phone To silence an audible alarm 1 Enter your code and press v After the system is disarmed the window will continue to display the number s of the zone s violated 2 To reset the display note the zones violated then press y Ambush Optional Your Ambush Code Type is TYPE 1 Prefix TYPE 2 Unique My Ambush Code is ___________________ If an intruder forces you to dis...

Page 11: ...ill be on After the alarm condition is corrected thermostat cooled down smoke cleared from detector etc pressing y again will reset the keypad within about 10 seconds Fire Zone Trouble The system is constantly monitoring the Fire Zone s to insure they are in good working order If a problem on a Fire Zone is detected a system trouble E41 will display followed by the number of the Fire Zone in troub...

Page 12: ... with all those who use the building 1 In a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals escape quickly Do not stop to pack 3 Test the door If it is hot use your alternate route through the window If the door is cool brace your shoulder against it and open it cautiously Be ready to slam the door if smoke or he...

Page 13: ...13 FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below Floorplan ...

Page 14: ...res because the fire may be a slow smoldering low heat type producing smoke because they may not be near the fire or because the heat of the fire may bypass them These detectors will not detect oxygen levels smoke toxic gases or flames Therefore they may only be used as part of a comprehensive fire detection system in conjunction with other devices Under no circumstances should thermostatic heat d...

Page 15: ...turn to its normal operating mode if no activity is detected for longer than one minute Display Zone Status Displays the zone number of zones that are not secured Press the ª p and z buttons as displayed on screen to scroll faulted zones Display Zones Bypassed Displays bypassed zones Press ª p and z to scroll bypassed zones Activate Bell Test Activates the alarm while disarmed for about 2 seconds ...

Page 16: ...one at the keypad when the programmed zone is opened while disarmed To deactivate the Chime Mode execute Function 7 once again Note The Chime Mode is disabled while armed 8 Activate Watch Mode Optional Watch Mode programmed YES NO This optional feature simultaneously turns on all zones designated as Day Zones which will cause an indication at the keypad if a zone is opened while the system is disa...

Page 17: ... To reset press y to clear the display enter the Function Menu scroll to Reset Sensor Watch Failure and press v If you cannot correct the problem call for service 11 Start Exit Time Optional Start Exit Time programmed YES NO In Commercial Burglary systems exit delay may have been programmed to start after a central station ringback verification signal has been received If the ringback tone has not...

Page 18: ...o 4 hours To Delay Arm the system With Function 16 in the window enter the desired Delay Arming time in hours 1 2 3 or 4 followed by v At the end of this 1 4 hour Delay Arming period the siren will sound a 2 second warning and the keypad will begin a 15 minute arming countdown with the sounder pulsing The sounder may be silenced at this time by pressing y but it will turn back on with a steady war...

Page 19: ... or off press ª p to proceed to the next group or z to scroll back to the previous group Press y when done Relay Group 01 ____________________________________ Relay Group 02 ____________________________________ Relay Group 03 ____________________________________ Relay Group 04 ____________________________________ Relay Group 05 ____________________________________ Relay Group 06 __________________...

Page 20: ...elled during the Abort De lay or cancelled after the report is sent and an acknowledgement of the can cellation is received a C will appear in the keypad window Regular Burglary Non 24 Hour Zone reports are aborted by disarming within the delay period 24 Hour Zones and zones programmed to report restores must be restored first then the panel armed and disarmed all within the delay period Opening a...

Page 21: ...call for service Function 11 Start Exit Time may then be used to manually start the exit delay however reporting capability may be sacrificed If your system does not report or the ringback feature was not programmed exit delay will start as soon as your code is entered Also note that if an exception window is programmed and the closing is within that window no ringback is provided Ask your alarm p...

Page 22: ... Reprogramming a User Code 1 Press w followed by the the 2 digits of the user number to be programmed Example for User 4 enter 04 2 Press w followed by the new User Code Note User Codes may be up to 6 digits in length For User Codes shorter than 6 digits use G0 for remaining digits 3 Press w repeatedly until UP is displayed 4 Press v to save the new User Code Note Duplicate Codes are not allowed t...

Page 23: ...5 Press y to exit the Program Mode Notes If the system contains more than one keypad only the keypad designated No 1 may be used for programming if in doubt as to which is No 1 ask your installer While in Program Mode the ARMED and STATUS lights remain off and burglar and fire alarm functions are disabled In selecting your codes do not program repetitive numbers 1111 consecutive numbers 1234 your ...

Page 24: ...Turning the system on off by entering your code at the keypad then pressing v Battery Backup power source in the control panel enclosure to provide protection in the event of a power failure BYPASS x Button Enables you to manually remove one or more protective zones from the system Central Station Monitors incoming reports and emergency messages from a digital communicator and notifies the proper ...

Page 25: ...Report A transmission to a central station notifying of a change in the status of the system alarm trouble low battery etc RF Low Battery Wireless systems only Weak transmitter battery RF Supervisory Wireless systems only Periodic test report from transmitter if a report is not received on time a supervisory failure system trouble will result Ringback A beep after arming verifying the central stat...

Page 26: ...ace through the normal exit entry door first Fire Zone Detects fire alarms or trouble conditions Interior Zones Circuits within the premises usually including space protection devices interior doors etc but not exterior doors or windows These can all be bypassed simultaneously by pressing p Two groups of Interior Zones may be programmed for each area Priority Zone A zone that prevents arming if in...

Page 27: ...Trouble Condition Action E 01 AC Power Failure This trouble will occur if AC power is not present Make sure system transformer is plugged into AC receptacle and check the circuit breaker otherwise call installing company for service E 02 Low Battery If there has been a recent power failure the battery may be partially depleted and must be recharged by the control panel The control panel performs a...

Page 28: ...GB The replacement battery for the GEM SMK is the Duracell MN1604 9 Volt Alkaline 2 required The GEM DT Dual Technology Sensor requires 4 C cell alkaline batteries Warning Replace batteries only with the same type as specified above Use of another battery may present a risk of fire or explosion Do not recharge or disassemble battery or dispose of in fire E 06 NN Receiver Response Failure Call inst...

Page 29: ... service E 15 NN RF Transmitter Tamper Wireless Transmitter Tamper Cover removed NN Transmitter Number Call installing company for service E 16 NN Wireless Receiver Jam A problem has been detected with the wireless receiver Call installing company for service E 17 NN Receiver Tamper Condition Call installing company for service E 18 NN KeyFob Transmitter Low Battery The batteries 2 in the wireless...

Page 30: ...stalling company for service E 24 Service Message The system is in need of a preventive maintenance service call E 27 00 Printer Failure Call installing company for service E 39 00 Receiver Capacity Error Call installing company for service E 40 NN RF Self Test Failure A wireless motion sensor on the zone indicated has failed its automatic self test routine Call installing company for service E 41...

Page 31: ... the scrolling error codes which represent the trouble Press y and you will now be able arm to the system but the trouble must be fixed as soon as possible See Page 7 27 The Fire Alarm is sounding and I don t know how to turn it off If a fire is in progress evacuate the premises immediately If necessary call the Fire Department from an outside telephone If there is no evidence of a fire enter your...

Page 32: ...o any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expected NAPCO does not represent that the product system may not be compromised or circumvented or that the product or system will prevent any personal injury or property loss by burglary robbery fire or otherwise nor that the product or system will in all c...

Reviews: