WP015(v1.0)2017-05-05
Fig4. Module backward installation diagram
The installation parameters are as follows
:
Table 2 Module installation parameters
Note:
In forward applications, the coverage width of the blind area on both sides is higher. It will be
recommended to adjust the installation azimuth to 45°. However, in backward applications, it
has a higher requirement for the longitudinal coverage in the BSD / LCA and others. And the
recommended installation angle and the body angle (azimuth) is typically 25°.
Radar directions are specified as shown in the following figure.
Fig5. The sign of angle direction is
specified as po)
Fig6. The sign of angle direction is
specified as ne)