Page 18
M4 SCREWS
12. SERVICE ‘C’ INSTRUCTIONS
(Every 6,000 hrs or 12 months)
Figure 1.
2. Loosen the 4x M5 screws to remove the
top cover. (See Figure 1)
4. Remove the screw from the sensor plug
and detach it from the dew point sensor
assembly. (See Figure 3 & 4)
SENSOR
PLUG
SCREW
SENSOR
PLUG
CONTROLLER
CHASSIS PLATE
1. Ensure the dryer is shutdown and
fully depressurized before attempting any
maintenance work.
Refer to:
CH. 6.MAINTENANCE GUIDELINES.
3. Release the catches located at the top and
bottom of the shroud to open it.
(See Figure’s 1 & 2)
ES MODELS ONLY
DEWPOINT SENSOR REPLACEMENT
NSK-130
Figure 3.
Figure 4.
Figure 2.