8x M12 CAP HEAD
SCREWS
TOP
MANIFOLD
(Every 24,000 hrs or 4 Years)
8. SERVICE ‘B’ INSTRUCTIONS
OUTLET VALVE REPLACEMENT
Please refer to figure 1
1. Ensure the dryer is shutdown and fully depressurized before attempting any maintenance work.
Refer to:
CH. 6.MAINTENANCE GUIDELINES
2. Remove the 4x M5 screws to remove the dryer top cover.
3. Remove the 8x M12 cap head screws and 8x washers to remove the top manifold from the dryer column and
support front shroud.
4. Using a pair of circlip pliers, remove each circlip.
CIRCLIP
VALVE SEAT
CHECK VALVE
DU BUSH
MODELS:
NBA- 070, 090, 110, 120
CVK-130
Figure 1.
GASKET SEAL