Make sure that the lip seal of the stuffing gasket is not
-
torn and that it has not lost its elasticity. to insert it,
position the gasket just beyond the shaft undercut.
Insert the impeller to reach the bottom. The stuffing
gasket will assume the correct position (see fig 31).
Wash all the components by using sanitising products
-
(observe the dosage recommended by the producer).
Make sure that all visible residuals and films are me-
chanically removed. Use pipe cleaners and brushes, if
necessary.
sanitise by making use of sanitising products.
Dip the components into a container with the sanitising
-
solution you have prepared before for about 20’.
reassemble the collection boxes and the water fun-
-
nels.
reassemble the powder deposit drawers and the
-
powder funnels after having carefully rinsed and dried
them up.
on reassembling the impellers, make sure that you will
-
insert them as far as the bottom, until you hear them
click.
Before closing the mixer compartment, lower
-
down all powder ports.
after having assembled the parts, act as follows,
any way:
access the “Filler” mode to wash the mixer (see the
-
relative paragraph) and add some drops of the sanitis
-
ing solution into the various funnels.
after having sanitised, rinse the parts abundantly to
-
remove any residue of the solution in use.
m
ixer
spouTs
If it had been necessary to disassemble the instant shelf,
pay attention to the spout/pump combination in use
before during the reassembly phase.
assemble 1-hole spouts in such a way that the water
inlet into the mixer will occur from the lower coupling.
any considerable variation in the doses of a drink may
require the replacement of the corresponding spout to
keep a correct flow rate.
Spouts having a different flow rate are identified by the
colour and number of holes:
spout
flow rate
Magenta (1 hole)
9 - 11 cc
Orange (1 hole)
11 - 13 cc
Magenta (2 holes)
19 - 22 cc
Orange (2 holes)
22 - 25 cc
White (1 hole)
22 - 25 cc
If you change the spout, you shall set up the type of
spout in the software of the machine (in the pump cali-
bration function from the technician menu).
the white spout is used to dispense hot water only.
at the end of the procedure, test the selections using
that mixer to be sure that the dispensing cycle of drinks
is correct.
Fig. 32
Pump
1-
(single or double) spouts
2-
Upper coupling
3-
Lower coupling
4-
Mixer
5-
Dispensed drink
6-
Summary of Contents for Canto LB 3600
Page 2: ......
Page 5: ......
Page 6: ......
Page 62: ...sx00300 ...
Page 63: ...LB 3600 Canto 230V ...
Page 64: ...Sx48501 ...
Page 65: ...Canto ...
Page 66: ...sx48700 ...
Page 67: ...Canto Door ...
Page 72: ......