Page PB
6-3-3-1
Switch Test
a.
Select “SWITCH TEST” on the menu screen and press the start
button. The following screen is displayed.
b.
Operate the accelerator lever and start button together to return to
menu screen
I/O TEST
TEST SW
ON
............... (a)
COIN SW
OFF
............... (b)
SERVICE SW
OFF
............... (c)
START BUTTON
OFF
............... (d)
ACCEL LEVER
0000
0000
FREE ............... (e)
SWING
0000
0000
CENTRE ........... (f)
HANDLE POLE
0000
0000
............... (g)
START+LEVER:EXIT
(a)
Test Switch:
“ON” during test mode.
(b)
Coin Switch:
‘OFF’ will change to ‘ON’ when the coins to the
correct game value have been inserted through
the Cashflow acceptor or the coin switch is
operated (S18 mech).
(c)
Service Switch
‘OFF’ will change to ‘ON’ each time the service
switch is pressed.
(d)
Start button
‘OFF’ will change to ‘ON’ each time the start
button is pressed. The button lamp will light
each time the button is pressed.
(e)
Accelerator Lever
‘FREE’ will change to ‘OK’ each time the lever
is operated fully.
(f)
Ship Swing
‘CENTER’ is displayed when in the central
stand by position.
‘RIGHT’ and ‘OK’ is displayed when swung fully
to the right.
‘LEFT’ and ‘OK’ is displayed when swung fully
to the left.
(g)
Handle Pole
‘UP OK’ is displayed when the control arm is
fully raised, ‘‘DOWN OK’ is displayed when the
control arm is fully lowered.
NOTE: If ‘OK’ does not appear when the ride is swung to its extreme
travel, re-initialize the game as described in section 7