Trouble
Cause
Inspection / Corrective Active
Motor does not rotate.
Control Button (CTRL)
⑲
is set to Auto
mode but trying to manually start with the
START / STOP Button (START/STOP)
⑯
on the Control Panel
②
.
Start with an External Command Signal
or set the Control Button (CTRL)
⑲
on the
Control Panel
②
to Manual mode. (When
Start with an External Command Signal,
refer to P80 " 16 - 1 (1) Details of External
Input / Output Connector A
③
Signals
Table. 6 Pin No. 14 " )
When started the
motor, " EE " is
displayed and motor
does not rotate.
Emergency Stop Signal is ' OFF (Open) '.
Check the setting of parameter
.
(Refer to P108 " 18 - 4
⑪
Selection of
Emergency Stop Function " section.)
When starting the
motor, " E7 " is
displayed and motor
does not rotate.
Low air pressure.
Adjust to the air pressure 0.25 - 0.3MPa
(36.3 - 43.5psi).
An Error Code occurs
and motor does not
rotate.
An Error has occurred. (Error LED
(ERROR)
㉒
is lit.)
Check the P94 " 17 - 3 Resetting System
after Error Codes Table. 9 ".
Error will not be released until cause of the
error has been removed.
Cannot set the
increase or decrease
of the motor rotation
speed.
When using Motor No. 1 :
Motor Fixed Speed is set in the
or
parameter.
When using Motor No. 2 :
Motor Fixed Speed is set in the
or
parameter.
Cancel the parameters for " Fixed Motor
Speed Setting " and " Maximum Motor
Speed Setting ".
When using Motor No. 1 :
Refer to P105 " 18 - 4
③
Setting Fixed
Motor No. 1 Speed " or P105 " 18 - 4
⑤
Setting Maximum Motor No.1 Speed ".
When using Motor No. 2 :
Refer to P105 " 18 - 4
④
Setting Fixed
Motor No.2 Speed " or P106 " 18 - 4
⑥
Setting Maximum Motor No.2 Speed ".
Speed is set
incorrectly when
using a pulse signal
in External Speed
Control Mode.
An unallowable pulse-train signal was
input.
Refer to parameter
.
(Refer to P100 " 18 - 3
⑦
Selection of
External Speed Control Mode ".)