96
18 - 2 Parameter Types
Parameter types, contents, and default are detail in Table. 10.
When checking a parameter or changing a setting, refer to P104 " 18 - 4 Setting procedures " section.
Code
Types
Contents
Default
Setting of Error Output Mode
Changes the Error Output Signal, when an error occurs
from normally open to normally closed.
Setting AUTO Mode for Motor
Speed Control
When the control is in AUTO mode, the speed
control is adjustable from the Control Panel
②
of the
CONTROLLER, set the parameter to
to adjust the
speed in AUTO Mode.
Setting Fixed Motor No. 1 Speed
When Fixed Motor Speed is desired, set the parameter
to
.
* Settable Motor Speed range is 1,000 - 50,000min
-1
in
1,000min
-1
increments.
* When the Motor Rotation Speed set in parameter
is higher than the Motor Rotation Speed set in
parameter
, the actual motor rotation speed will
be the rotational speed that was set in the parameter
.
Setting Fixed Motor No. 2 Speed
When Fixed Motor Speed is desired, set the parameter
to
.
* Settable Motor Speed range is 1,000 - 50,000min
-1
in
1,000min
-1
increments.
* When the Motor Rotation Speed set in parameter
is higher than the Motor Rotation Speed set in
parameter
, the actual motor rotation speed will
be the rotational speed that was set in the parameter
.
Table. 10
CAUTION
When in the parameter mode, normal operation of starting, stopping, etc. operation is not possible.
When changing from the parameter mode to normal operation, be sure to toggle the Main Power
Switch
⑨
OFF and ON again.
18. SETTING OF OPERATING PARAMETERS
18 - 1 Entering Parameter Setting Mode
(1) Make sure that the Main Power Switch
⑨
is turned OFF.
(2) While pushing and holding the Error Reset Button (RESET)
㉑
while turning the Main Power Switch
⑨
ON at
the front of the CONTROLLER.
(3) Hold the Error Reset Button (RESET)
㉑
down for 3 seconds while the CONTROL is powering up.
(4) The buzzer will ' BEEP ' 3 times, then release the Error Reset Button (RESET)
㉑
and Parameter Setting
Mode will start.
is Displayed.