233
8-5. System Registers
Address
7
8
14
20
26
31
Name of system register
Hold area starting
address settings for
internal relays
Hold area starting
address settings for
data registers
Hold/non-hold setting for
step ladder
Operation settings for
duplicated use of output
Operation settings when
an operation error occurs
Waiting time settings for
multi-frame communication
Default
value
K10
K0
K1
K0
K0
K2600
(6500 ms)
Description
Hold area starting address for internal relays is specified in
word-units.
• Setting range
C14/C16 series:
C24/C40/C56/C72 series:
• If the maximum value of the setting range is input, all of
the areas are used as non-hold areas.
EXAMPLE:
If system register 7 of C14 series is set to K5:
- Non-hold area:
- Hold area:
Hold area starting address for data registers is specified.
• Setting range
C14/C16 series: K0 to K256
C24/C40 series: K0 to K1660
C56/C72 series: K0 to K6144
• If the maximum value of the setting range is input, all of
the areas are used as non-hold areas.
EXAMPLE:
If the system register 8 of C14 series is set to K10:
- Non-hold area:
- Hold area:
Hold/non-hold setting for step ladder operation is specified.
K0: Hold
K1: Non-hold
This register specifies the operation of the FP1 when a
duplicated use of output is programmed.
K0: a duplicated use of output is regarded as a
total-check error.
K1: a duplicated use of output is not regarded as an
error.
This register specifies the operation of the FP1 when an
operation error is detected.
K0: FP1 stops operation if an operation error occurs.
K1: FP1 continues operation even if an operation error
occurs.
This register specifies the maximum waiting time between
delimiters when multi-frame communication is performed
with the computer link.
• Setting range
K4 to K32760: 10 ms to 81.9 s
• The formula to calculate the waiting time is:
set value
×
2.5 ms
Note:
- When you set this register using NPST-GR Software, set
a time that can be divided by 2.5.
K0 to K16
K0 to K63
R0 to R4F
R50 to R15F
DT0 to DT9
DT10 to DT255
Summary of Contents for FP1
Page 1: ...PROGRAMMABLE CONTROLLER FP1 is a global brand name of Matsushita Electric Works Hardware ...
Page 28: ...20 ...
Page 98: ...90 ...
Page 150: ...142 ...
Page 208: ...200 ...
Page 226: ...218 ...
Page 280: ...272 ...