5-3. Description of Basic Instructions
126
Outline
Indicates the end of a main program.
Program example
■
Explanation of example
• Step 50 is the end of the main program area.
Description
• Indicates the end of a main program.
Notes:
• Place any subroutine programs and interrupt programs after the
ED
instruction.
• Use the
CNDE
instruction if end processing is necessary within the main program.
Refer to FP-M/FP1 Programming Manual, for details about the
CNDE
instruction.
• Refer to page 139, “5-4. Hints for Programming Basic Instructions”, for details about basic instructions,
such as the
ED
instruction, which are not displayed on the FP Programmer
II
keys.
ED
End
Availability
Step
1
All series
Ladder Diagram
FP Programmer
II
key operations
Boolean Non-ladder
Address Instruction
X0
(
ED
)
!
0
50
Y0
ST
X-WX
ST
X-WX
0
WRT
AN
Y-WY
OT
L-WL
0
WRT
SHIFT
SC
0
WRT
SHIFT
SC
1
•
•
•
•
0
1
.
.
.
.
50
ST
X
0
OT
Y
0
.
.
.
.
ED
Main program
Subroutine program
Interrupt program
0
(ED)