Use a separate power outlet fitted with a grounding wire. Tight the power plug when in 
use. 

 

 

Put off the power plug, before removing the equipment. 

 

 

Carefully touch the inner wall of the door, which may be hot. 

 

 

Nonprofessional technical staff could not disassemble the machine privately, professional 
staff should repair and replace parts. 

 

 

The  internal  parameters  must  be  set  by  the  specific  management  person  to  prevent  the 
function of the controller program from being disturbed by do not know setting operation. 

 

 

The installation location of the equipment must be longer than 20 cm from the wall and 
from the object. 

 

 

Open  or  close  the  door  gently.  Rudely  opening  or  closing  the  door  can  easily  cause 
damage to the equipment. 

 

 

The surface of the equipment must not be exposed to volatile chemicals such as gasoline 
or thinner. 

 

 

Keep the inside and outside of the box clean, often cleaning debris and smudges. 

 
 

 

 

 

1.  The  large  screen  LCD  displays  the  temperature,  speed  and  working  time  continuously, 
accurately and in real time, and the menu operation interface is easy to operate. 
2.  Microcomputer  controlled  temperature  and  oscillation  frequency,  with  timing  function, 
built-in  power  failure  protection  function,  can  automatically  resume  operation  after  normal 
power supply. 
3.  The  unique  air  duct  of  the  workshop  has  a  gentle  breeze  circulation,  good  temperature 
uniformity, large observation window design, convenient observation of samples, convenient 
opening and closing. 
4.

 

Speed control: DC brushless motor intelligent feedback control, high speed accuracy. Slow 

start  design,  when  the  speed  is  out  of  control,  automatic  locking,  adjustable  start  speed, 
prevent the sudden start of the shake flask liquid spatter, effectively ensure the accuracy of the 
quantitative experiment.

2. Product main features

 

Summary of Contents for LNB003

Page 1: ...Version 1 July 2021 Instruction Manual NAHITA BLUE SHAKING INCUBATOR REFERENCE LNB003...

Page 2: ...r the appearance of the product is intact and the random accessories matches the packing list If the product model you received is inconsistent with your booking or the appearance is damaged or there...

Page 3: ...et hands otherwise there is a risk of electric shock 4 Before any repair or maintenance is carried out the power must be disconnected to prevent electric shock or injury 5 Please wear gloves when repa...

Page 4: ...als such as gasoline or thinner Keep the inside and outside of the box clean often cleaning debris and smudges 1 The large screen LCD displays the temperature speed and working time continuously accur...

Page 5: ...W Controller Temp Control Mode LCD PID intelligent control Cyclotron Control Mode Automatic changes of rotation direction Setting Mode Touch button setting Temp Display Mode LCD display Speed Display...

Page 6: ...key thermometer symbol press enter temperature parameter setting state then click return to normal interface Speed function key with arrowhead circle press enter speed parameter setting state then pr...

Page 7: ...0 5 0 Ct Compressor start delay Compressor start delay protection time the minimum time interval from compressor stop to restart 0 600s 180 uP compressor Start threshold When the compressor is workin...

Page 8: ...essor 2 compressor according to the value of Htd see below to determine the balanced or intermittent work of the compressor 0 2 0 CP Compressor working mode fixed switching point point When ndc 1 If t...

Page 9: ...password prompt Lc The speed display area displays the password value You can change the password value to the required password value by adding the key decreasing key and shift key Then click the Sp...

Page 10: ...tion dIF 0 Specifies that the clockwise direction of rotation is positive dIF 1 Specifies that the counterclockwise direction of rotation is positive 0 1 0 FdS Speed feedback value Speed feedback coef...

Page 11: ...by shifting reducing increasing etc then click the Time button to enter the stop timing time the right display prompt p setting status Also modify to the desired setting value then click the Time butt...

Page 12: ...light up and enters after about 3 seconds Normal display status 2 Temperature Press the Temperature button the number on the right side of the temperature display area flashes use the shift button de...

Page 13: ...the operation Notes 1 If the set value of the timing time is changed during the running the controller restarts the timing according to the new set time 2 The timing mode can be selected by modifying...

Page 14: ...ng state the controller will automatically return to the normal display state 5 If the display window of the controller shows to indicate the fault of the temperature sensor or the controller itself p...

Page 15: ...ed smoothly Adjust the foot of the instrument to make the instrument smooth Foreign body barrier at the bottom of the plate Remove foreign body Control circuit fault Notify distributor to repair The m...

Reviews: