Insensitive area

 

dF- 

False display 
interval point

 

When  the  speed  set  value 

  dF,  both 

the speed set value and the speed display 
value are false display values.

 

(0

6000) 6000 

 
 

3.

 

Time setting 

 
1.

 

When Fr is set to 

0

  or 

1

  in 

Speed---Internal Parameter Table (2)

, it can only 

be forwarded or reversed: press the 

Time

  button, the number on the right side of the time 

display area will flash. Use the 

  shift button, 

“▼”

  decrease button, 

“▲”

  increase 

button to set the running time, press the 

Time

  button again to return to the work interface, 

and the time display area displays  the set  total.  Timing  time, the number decreases with  the 
running time, and the integer stops. Finally, it stops and the buzzer sounds. Press any key and 
the buzzer will stop. 

2.

 

When  Fr  is  set  to  "2"  in  "Speed  -  Internal  parameter  table  (2)",  there  is  a  positive  and 

negative function: Click the "Time" button to enter the total timing setting state, and the time 

display  area  flashes.  You  can  use  the  '

'  shift  key,  '

'  decrease  key,  '

'  increase  key  to 

modify the desired set value; then click the 

time

  key to enter the forward rotation time (the 

prompt  Fd  is  displayed  on  the  right).  )  Set  the  status,  modify  the  desired  setting  value  by 
shifting, reducing, increasing, etc.; then click the 

Time

  button to enter the stop timing time 

(the right display prompt p-) setting status, Also modify to the desired setting value; then click 
the 

Time

  button to enter the reverse timing time (the right display prompt Rd) setting state, 

also modify to the desired setting value; then click the 

Time

  button , returns to the normal 

display state. Complete the time setting. 

 

Note:  The  total  time  can  be  selected  in  minutes  and  hours;  the  forward,  stop,  and  reverse 
timings are minutes. 

 

3.  Press  and  hold  the  “Time”  button  for  about  3  seconds.  The  temperature  display  area 
displays the password prompt “Lc”, and the speed display area password value is modified to 
the required password value by the increase, decrease and shift keys. Then click the “Time” 
button.  If  the  password  value  is  incorrect,  the  controller  will  automatically  return  to  the 
normal display state. If the password value is correct, it will enter the time internal parameter 
setting  state,  and  then  click  the  “Time”  button  to  modify  each  parameter  in  turn.  Press  and 
hold  the  “Time”  button  for  3  seconds  to  exit  this  state  and  the  parameter  values  are 
automatically saved. 

 

Time---internal parameter table 

 

Parameter 

indication 

parameter 

name 

Parameter function description 

(Range) Factory 

Value 

Lc-

 

 

Password 

The  parameter  values  can  be  viewed  and  modified  when 
"Lc=3". 

Summary of Contents for LNB003

Page 1: ...Version 1 July 2021 Instruction Manual NAHITA BLUE SHAKING INCUBATOR REFERENCE LNB003...

Page 2: ...r the appearance of the product is intact and the random accessories matches the packing list If the product model you received is inconsistent with your booking or the appearance is damaged or there...

Page 3: ...et hands otherwise there is a risk of electric shock 4 Before any repair or maintenance is carried out the power must be disconnected to prevent electric shock or injury 5 Please wear gloves when repa...

Page 4: ...als such as gasoline or thinner Keep the inside and outside of the box clean often cleaning debris and smudges 1 The large screen LCD displays the temperature speed and working time continuously accur...

Page 5: ...W Controller Temp Control Mode LCD PID intelligent control Cyclotron Control Mode Automatic changes of rotation direction Setting Mode Touch button setting Temp Display Mode LCD display Speed Display...

Page 6: ...key thermometer symbol press enter temperature parameter setting state then click return to normal interface Speed function key with arrowhead circle press enter speed parameter setting state then pr...

Page 7: ...0 5 0 Ct Compressor start delay Compressor start delay protection time the minimum time interval from compressor stop to restart 0 600s 180 uP compressor Start threshold When the compressor is workin...

Page 8: ...essor 2 compressor according to the value of Htd see below to determine the balanced or intermittent work of the compressor 0 2 0 CP Compressor working mode fixed switching point point When ndc 1 If t...

Page 9: ...password prompt Lc The speed display area displays the password value You can change the password value to the required password value by adding the key decreasing key and shift key Then click the Sp...

Page 10: ...tion dIF 0 Specifies that the clockwise direction of rotation is positive dIF 1 Specifies that the counterclockwise direction of rotation is positive 0 1 0 FdS Speed feedback value Speed feedback coef...

Page 11: ...by shifting reducing increasing etc then click the Time button to enter the stop timing time the right display prompt p setting status Also modify to the desired setting value then click the Time butt...

Page 12: ...light up and enters after about 3 seconds Normal display status 2 Temperature Press the Temperature button the number on the right side of the temperature display area flashes use the shift button de...

Page 13: ...the operation Notes 1 If the set value of the timing time is changed during the running the controller restarts the timing according to the new set time 2 The timing mode can be selected by modifying...

Page 14: ...ng state the controller will automatically return to the normal display state 5 If the display window of the controller shows to indicate the fault of the temperature sensor or the controller itself p...