GT1175 Slide Door Opus Control Wiring and Programming Manual
Rev. 8-11-21
P/N C-00391
SECTION 3.9: Relay Output Terminal Strip
Relay Output 3
COM Common Input
N.C.
Normally Closed Contact
N.O. Normally Open contact for Sensor Monitoring
SECTION 3.10: CAN Bus Communication
Used to connect Sim Pair, Astragal, Sequencing and the NET-HT Cable when programming.
SECTION 3.11: Simultaneous Pair
Bi-Part Units installed with panels larger and/or heavier than standard panels, require (2) Drivetrains. (2) Drivetrains require (2) Opus
Controls. (2) Opus Controls installed inside (1) Header must be programmed as a Sim-Pair (same as a swing door). (2) Opus Controls
are installed inside the Header and programmed as a Sim-Pair at the NABCO Factory.
CHAPTER 4: LCD CATEGORY SCREENS
Passcode
Go to Se ng Menu
Stroke Learning
Yes No
UNIT SPECS
ERROR
ANSI
TERMINAL
Long
Push
LEVEL 1
LEVEL 2
Rotate Dial to navigate screen. Short Push Dial to select
Se ng Category
LEVEL 3
Parameter
Op ons
Base Se ng
Operator Type/Low or Full Energy/Handing/Encoder
Movement Se ng
(Rotate Rotary Dial)
Open Speed/Back Check Speed/Back Check Range/Close Speed/Latch Check Speed/
Latch Check Range/Open Timer/Reac on Power/Open Recycle Sens/Close Recycle Sens/
A er Open Recycle
Op onal Se ng
Hold Close Force/Power Close Range/Manual Open Func on/Manual Open Sens/Manual
Open Timer/BCHK Lockout Angle/LCHK Lockout Angle/Stop Force adjustment/SimPair Se ng
Output Se ng
Output1 Se ng/Output2 Se ng/RelayOutput3 Se ng/Open Delay Timer/
Sequence Delay Timer/Lock Condi on
Input Se ng
Input 62 Se ng/Input 62 Open Timer/Input H Se ng/Input H Open Timer/Input 61 Circuit/
Input 62 Circuit/Input 6B Circuit/Input SWL Circuit/Input BA Circuit/6B Stop Closing/A er 6B
Open?/61 Monitoring/62 Monitoring/6B Monitoring/SWL Monitoring
History Data
Opera on Cnt/Open Recycle Cnt/Close Recycle Cnt/Latest Recycle Posi on
DN 1334
LEVEL 4
Push and Hold Rotary Dial (2 Sec.)
Rotate
Dial
Rotate
Dial
Rotate
Dial
Short
Push
Figure 2
LCD Screen Transition
SECTION 4.1 Level One: Specification Screens
Type:
GT710 Swing
Status:
Slow Closing
Error:
-----
Ac va on: IN EXT
Posi on:
> > > > > > >
Other:
BA 6B SLS
Keep Pushing Switch
=> Se ng Mode
DN 2430
UNIT SPECS
ANSI specs (reference)
Opening Time to 80 deg
Closing Time to LCHK
LCHK to FullClosed
8
BA
1 12VDC
9
SQ
2 GND
10 Mul
3 61
11 M0
4 62
12 M1
5 6B
13 Out3
6 SWL
14 GND
7 Out2
Terminal
Error Screen
Mfg: 11/2016 Rev.B:21
Rotate
Dial
Rotate
Dial
Rotate
Dial
ANSI SPECS
ERROR SPECS
TERMINAL SPECS
Fully Closed
GT1175 Opus Slide
Figure 3
Level One Screens