GT1175 Slide Door Opus Control Wiring and Programming Manual
www.NabcoEntrances.com
P/N C-00391
Rev 8-11-21
Input Setting
Parameter
Terminal
Default
Range
Description
61 Monitoring
N/A
Active
►
Active
►
Not Active
Sensor monitoring function *
62 Monitoring
N/A
Active
►
Active
►
Not Active
Sensor monitoring function *
6B Monitoring
N/A
Active
►
Active
►
Not Active
Sensor monitoring function *
SWL Monitoring
N/A
Not Active
►
Active
►
Not Active
Sensor monitoring function *
* If monitoring is enabled for any input, a sensor must be connected to that input that is capable of monitoring. That sensor’s
input must then be connected to an Opus output programmed for monitoring. If this is not done, errors will occur resulting in
the door not operating until the problem is fixed.
* Monitoring settings are “OFF” by default except when used as “1175 Opus Slide”, in which case standard settings have
monitoring enabled.
SECTION 8.6: History Setting
History Data
Parameter
Description
Operation Cnt
►
Indicates number of Door open cycles.
►
Updated every 100 door cycles.
Open Recycle Cnt
Indicates number of times the Door reversed direction during Opening cycle after sensing:
►
An object was struck.
►
The amount of friction that surpassed the recycle sensitivity setting.
Close Recycle Cnt
Indicates number of times the Door reversed direction during Closing cycle after sensing:
►
An object was struck.
►
The amount of friction that surpassed the Recycle Sensitivity Setting.
Latest Recycle Position
►
Indicates the last recycle position during opening and closing.
►
For swing doors it displays the approximate angle from closed at recycle. For slide doors it displays
the position in inches from closed.
SECTION 8.7: Test Open
<= Test Open =>
Tests Open/Close door cycle while ignoring Safety Signals.