27 of 31
www.NabcoEntrances.com
GT1175 Slide Door Opus Control Wiring and Programming Manual
Rev. 8-11-21
P/N C-00391
SECTION 11.9: Change Slide Door Mode with Remote Switch
REMO
TE DEVICE MUST BE A DR
Y CONT
AC
T
DN 2288
Op
on 1: R
emove
Ro
ck
er Swi
tc
he
s
1.
Re
move the R
ock
er Swi
tc
h.
2. Modify the R
ock
er Swit
ch e
xt
ension (
P/
N A-00967) shown belo
w.
a.
Re
d and Blue wi
re
s mus
t be connect
ed f
or the door to oper
ate.
b. Other wir
es should be capped off
to prevent shor
n
g.
Op
on 2: R
eplace R
oc
ke
r Swit
ches with K
ey Switche
s
1.
Re
place the
Ro
ck
er Swi
tc
h with the K
ey Switch.
2. K
eep the K
ey Switch in 2-
Wa
y.
3. Connect the R
emot
e Swit
ch to the Opus Contr
ol
:
• T
erminals 11 and 14
fo
r 1-
Wa
y.
• T
erminals 12 and 14
fo
r Night.
GREEN
RED
ORG/WH
T
BL
UE
ORANGE
RED
ORANGE
WHEN CONT
AC
T IS OPEN = 2-W
AY
WHEN CONT
AC
T IS C
LO
SED = 1-
WA
Y
WHEN CONT
AC
T IS OPEN = 2-W
AY
WHEN CONT
AC
T IS C
LO
SED = NIGHT
GREEN
RED
ORG/WH
T
BL
UE
ORANGE
RED
ORANGE/WHITE
SWIT
CH BETWEEN 2-W
AY
AND NIGHT
SWIT
CH BETWEEN 2-W
AY
AND 1-W
AY
Mode
M0 to Common Or
ange to
Re
d
Terminals 11 thru 1
4
M1 to Common
Or
ange/Whi
te
to
Re
d
Terminals 12 thru 1
4
Tw
o
Wa
y (Auto)
Open
Open
One W
ay
(Exit Only)
Closed
Open
Night
Open
Closed
Hold
Closed
Closed