13 of 31
www.NabcoEntrances.com
GT1175 Slide Door Opus Control Wiring and Programming Manual
Rev. 8-11-21
P/N C-00391
Movement Setting
Parameter
Range
Default
Description
Close Recycle
Reopen
Yes
Yes
Determines what happens after a recycle while closing cycle.
►
Yes = Door re-opens
►
No = Door stops then slowly closes
No
SECTION 8.3: Optional Settings
Optional Setting
Parameter
Range
Default
Description
Hold Close Force
0 - 3
0
0
OFF
3
Strongest Hold Close force
Sim Pair Setting
Single Door
Single
Door
Select type of Door
Normal Sim Pair
If selected; before returning to last screen, option to copy
settings to other Control is given.
Double Egress
The Activation signal (only) is shared between doors. All other
signals are independent.
Overlap Sim Pair
►
Overlap Sim Pair is for an Astragal Application.
►
Opus Control connected to door that must open first:
1. Have activation signals connected to it
2. Be set to “Overlap Sim Pair”
►
The delayed control will be set to “Normal Sim Pair”
►
Latch Check range is wider than normal setting.
►
If selected; before returning to last screen, the option to
copy settings to the other Control is given
Flip Screen
Yes
No
Choose Yes if Opus is installed upside down.
LCD will flip right side up when Control is upside down.
No