background image

12/1/2006 

FRONT PANEL 
 

 

 

 

From Top to Bottom: 

   

  Green LED lights when Power is connected 

RJ45 Ports   Auto sensing 10/100 BaseTX Connections 
Serial 

  RS232 serial port with DCE configuration 

 

NOTE:  The  RJ45  data  port  has  two  LED’s  located  at  the  left  side  of  the  connector.    The  top  LED  indicates 
Activity (ACT), and the lower LED indicates Link (LNK) status. 

 

LED’s:  The table below describes the operating modes: 

 

LED 

Color 

Description 

GREEN 

  Power is Applied 

 

OFF 

  Power is OFF 

GREEN 

10/100Mb Link between ports 

LNK 

OFF 

No Link between ports 

GREEN 

Data is active between ports  

ACT 

OFF 

Data is inactive between ports 

 
 

 

 

 

 

 
 

 

Summary of Contents for 102PC-SE

Page 1: ...12 1 2006 1 102PC SE Industrial Serial Ethernet Protocol Converter User Manual Installation Guide...

Page 2: ...e of Menus 20 Ethernet to Serial Connectivity 26 o Manual Dialout 27 o Auto Dialout using Telnet 28 o Auto Dialout using UDP 29 o Remote Bridging with Modem Connection 30 Serial to Ethernet Connectivi...

Page 3: ...nable any serial device to provide remote monitoring control and configuration of any serial device This device is ideal for the following applications Mounting legacy serial devices to the LAN Indust...

Page 4: ...cluded but not limited to lost profits arising out of errors or omissions in this manual or the information contained herein Warning Do not perform any services on the unit unless qualified to do so D...

Page 5: ...not operate the unit with the top cover removed WARNING Do not work on equipment or cables during periods of lightning activity WARNING Do not perform any services on the unit unless qualified to do...

Page 6: ...en fully tested and certified at industrial environmental extremes PACKAGE CONTENTS Please make sure the Serial over Ethernet package contains the following items 1 102PC SE Protocol Converter 2 Produ...

Page 7: ...ound at the bottom of the unit and apply downward force on the clip until it disengages from the bottom of the unit from the DIN rail Rotate the bottom of the unit towards you and up at an approximate...

Page 8: ...data port has two LED s located at the left side of the connector The top LED indicates Activity ACT and the lower LED indicates Link LNK status LED s The table below describes the operating modes LED...

Page 9: ...block power plug is 0 22 Nm 0 162 Pound Foot Verify the Power LED stays ON GREEN Note Only 1 power supply must be connected to power for minimal operation For redundant power operation V1 and V2 input...

Page 10: ...length As an alternate users can run a drain wire lug from any of the Din Rail screws or empty PEM nuts on the enclosure When using an unused PEM nut to connect a ground lug via a machine screw care...

Page 11: ...ble into the RJ45 connector Connect the other end to a PC or a network through a hub or switch A standard straight through or cross over Category 5E cable may be used to connect to either device The M...

Page 12: ...ns for a straight through cable PC DTE Device Cable End 102 PC SE Cable End DTE Device 25 Pin 9 Pin Port Female Female 9 Pin Female Signal Name Pin Pin Pin Signal Name DCD 8 1 1 DTR RXD 3 2 2 TXD TXD...

Page 13: ...tion 6 Verify that a null modem cable is being used to connect other DCE devices to the serial port or that a straight through cable is being used to connect a PC to the serial port SUPPORT Contact N...

Page 14: ...oadcasted over http banner set a string to be the http banner pri dns setup the primary DNS server in the format of xxx xxx xxx xxx sec dns setup the secondary DNS server in the format of xxx xxx xxx...

Page 15: ...enable or disable auto dialout auto dialout port set the port number for the auto dialout feature auto dialout protocol telnet baud rate Possible baud rate value s are 300 600 1200 1800 2400 4800 9600...

Page 16: ...t s0 statistics shows the data statistics of the activity over the serial port s0 o snmp agent config Shows the SNMP configuration settings o sntp client config Shows the SNTP configuration settings o...

Page 17: ...ket_handle send over a socket o stat s d socket_handle lists stats for sockets s socket only d socket detail o tcp remote_ip remote_port set up the tcp socket information o tcplisten local_port backlo...

Page 18: ...d for the unit it can be remotely configured through a web browser To configure it over a web browser simply enter the IP address in the web address line of the web browser You should be prompted to e...

Page 19: ...port Note If you can t find an option that you are looking to configure you may manually enter the command in through the web browser under the command link at the top of the page Don t forget to save...

Page 20: ...s multiTech socketProduct seipInfo seipIPSetup seipIPServiceSetup seipe Monitor Enables Disables monitor flag to scan escape sequence and switch to command mode during Manual dialin telnet session Def...

Page 21: ...ing will automatically disable PPP on the module Default disable IP Address Sets Bridge IP address Can be set only when Bridge is enabled Default Ethernet ip address IP Mask IP mask of the configured...

Page 22: ...les Disables Auto discovery to broadcast MAC Level the MAC address IP address and DHCP information to server port configured default 1020 Default enable Server Port Sets the Auto Discovery Manager Ser...

Page 23: ...t o Raw Dialin Enables Disables raw mode for Serial Auto Dialin session on the serial port s0 The session will be in Raw mode only if the global raw mode is enabled Default disable Autodialout Configu...

Page 24: ...Server port Default 25 Host Name Sets the SMTP Client Host Name Default NULL From Identity Sets the From description in the email header Default NULL From Address Sets the default From email address...

Page 25: ...use during the Day Light Saving Mode Default sunday Start Time Sets the start time to use during the Day Light Saving Mode Default 02 00 hh mm End Time Sets the end time to use during the Day Light Sa...

Page 26: ...t login auto dialout login enable disable Enable Disable the Switching between Dialout CommandPrompt feature set ip telnet escape monitor enable disable Set the Escape Monitor String to switch between...

Page 27: ...serial s0 stop bits 1 set serial s0 flow control rts cts save Once the above configuration is saved in the 102PC SE use a telnet client and connect to 192 168 1 202 on port 23 On successful login at t...

Page 28: ...port 5000 set serial s0 auto dialout protocol telnet set serial s0 baud rate 115200 set serial s0 data bits 8 set serial s0 parity none set serial s0 stop bits 1 set serial s0 flow control rts cts sa...

Page 29: ...gured port the 102PC SE locks the serial port for that UDP Client and latches to the UDP client address connected The UDP Client is now ready to send or receive data to or from the serial device How t...

Page 30: ...2 10 set bridge enable set bridge ipmodule ip address 192 168 2 10 set ppp ppp0 enable set ppp ppp0 raw mode enable Only if simple AHDLC quoting on the serial port is required set serial s0 connect t...

Page 31: ...t will be connected set serial s0 auto port port port_number An ERROR message will display if any of the above details are not configured or not valid Optional Configuration Settings The following det...

Page 32: ...p eth0 ip address 192 168 2 1 set serial s0 baud rate 115200 set serial s0 data bits 8 set serial s0 parity none set serial s0 stop bits 1 set serial s0 flow control rts cts save Once the above config...

Page 33: ...n ipaddress 192 168 2 10 set serial s0 auto dialin port 23 set serial s0 auto dialin protocol telnet set serial s0 baud rate 115200 set serial s0 data bits 8 set serial s0 parity none set serial s0 st...

Page 34: ...s 192 168 2 10 set serial s0 auto dialin port 23 set serial s0 auto dialin protocol udp set serial s0 baud rate 115200 set serial s0 data bits 8 set serial s0 parity none set serial s0 stop bits 1 set...

Page 35: ...o dialin ipaddress 192 168 2 10 set serial s0 auto dialin port 23 set serial s0 auto dialin protocol telnet set serial s0 baud rate 115200 set serial s0 data bits 8 set serial s0 parity none set seria...

Page 36: ...john smith bellsouth net Set an identity for this e mail address that you are sending from set send mail from address identity Smith The following items must be configured in order to receive e mails...

Page 37: ...n Password logged in successfully send mail t john smith bellsouth net s test d Testing e mail Features OK Mail sent send mail To john smith bellsouth net To To address not given Cc Cc address not giv...

Page 38: ...coding 7bit Message Id 20050525195032 PFUE1498 ibm61aec bellsouth net adsl 220 163 81 mobbellsouth net Testing e mail features OK Message 1 Received Return Path john smith bellsouth net Received from...

Page 39: ...rating Temp 0 C to 70 C Storage Temp 40 C to 85 C Operating Humidity 20 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Shock and Vibration bulkhead mounting Shock 200g 10ms Vibration Seismic 5...

Page 40: ...ES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S OP...