![MWP W4B-120C Installation And Operation Manual Download Page 14](http://html1.mh-extra.com/html/mwp/w4b-120c/w4b-120c_installation-and-operation-manual_1861119014.webp)
14
“Charge Mode LED” Blinking Green:
The wind charger is CHARGE CONTROL or DIVERSION CONTROL Mode and the battery
is not fully charged. AS the battery voltage approaches the BULK setting, the status LED
will blink green several times (up to five) and then pause, indicating the battery voltage is
approaching the BULK setting and provides an indication of the battery condition. Refer to
the table 1 to determine the battery voltage.
NOTE: A single green flash indicates the battery is below the bulk voltage setting. It does
NOT indicate the batteries are charging.
3 .3 Equalization Mode Indication
“Equalization LED” Blinking Orange:
The wind charger is in the Equalization Mode. It will automatically stop the equalization
process after accumulating setting Equalize Time of operation at Equalize Voltage above
the BULK setting.
The user can stop the equalization process at any time by pressing the reset pushbutton
until the status LED stops.
Battery Voltage (Using LED Status Indicator)
LED Status
Green LED (Charge/Diver-
sion Mode)
Always ON
Battery at FLOAT setting
5 Blinks
Battery at BULK setting
Bulk Setting Minus (-)
4 Blinks
0.25 VDC
0.50 VDC
1.00 VDC
3 Blinks
0.50 VDC
1.00 VDC
2.00 VDC
2 Blinks
0.75 VDC
1.50 VDC
3.00 VDC
1 Blinks
> 0.75 VDC
> 1.50 VDC
> 3.00 VDC
Below Bulk
Below Bulk
Below Bulk
DC Voltage
12 Volts
24 Volts
48 Volts
Table 1 Battery Voltage LED Indication