31
RVP165 - NLFREN - v1.0 - 10022015
EN
MACH
• In
Zone B
(manual solvent-washing) - the wash cycle is enabled by a small venturi pump (fig.1, 8) sucks dirty solvent,
while the nebulizer (fig.1, 22) and a small venturi pump (fig.1, 21) suck the clean solvent. The spray gun washer is fitted
with hoses to take in and out the different liquids from the bins positioned at the base of the machine. Solvent fumes and
vapours sprayed into the air inside the machine are automatically conveyed and sucked each time the operator opens the
upper door (fig. 1, 11) and exhausted given the venturi effect generated by the nozzle (fig.1, 15) inside the pipe (fig.1,
16). Before this exhausting pipe, an active carbon depurator (on request) can be applied to eliminate polluting gaseous
particles.
From the upper front control panel the operator can:
•
Control the pump (fig. 1, 32) for solvent (fig.1, W17)
•
Control the clean water nebulizer (fig.1, W18).
•
Adjust the air flow to mix water with the coagulating powder (fig.1, W1).
•
Control the clean water connected to the water mains of the company (fig.1, W18C).
•
Control the small Venturi pump of the dirty solvent (fig.1, 17).
•
Control the clean solvent nebulizer (fig.1, W18).
•
Control the small Venturi pump of the clean solvent (fig.1, 19).
Zone A - Water-washing
Zone B - Solvent-washing
W1
Flow regulator
3
Lower door magnet
W2
Water collecting basin
7
Small pump feeding hose
W4
Blowing gun feeding hose
8
Small venturi pump
W4A
Blowing gun
4
Spray-gun feeding hose
W6C
Grid top
10
Air outlet fitting
W7F
Small pump feeding filter
11
Upper door
W10
Air outlet fitting
11A
Lower door
W17
Small pump check valve
12
Compressed air inlet fitting with filter
W18
Nebulizer check valve
15
Vapour suction nozzle
W18C
Water control lever connected to the the
company’s water mains
16
Vapour exhauster (Ø 150 mm)
W22
Nebulizer
17
Venturi pump check valve
W22C
Fresh water discharge fitting
18
Nebulizer check valve
W23
Nebulizer feeding hose
19
Small pump check valve
W23C
Water inlet fitting
21
Small pump
W23R
Water throttle valve (to be connected to
fitting W23C and the company’s water
mains)
22
Nebulizer
W30
Tank discharge valve
23
Nebulizer feeding hose
W32
MP Diaphragm pump
24
Small pump feeding hose
W35
Air diffuser to mix water with coagulating
powder
25
Manual-washing grid top
W36
Washing brush
26
Grid top discharge hose
W36Z
Washing brush
27
Dirty solvent bin
W50
Prefilter bag
28
Clean solvent bin
W51
Filter bag
41
Automatic vapour suction check valve
W52
Pierced container
42
Upper door latch
W53
Clean water collecting container
46
Cover of the hood inspection hole
47
Collection tank
72
Control panel adhesive label
74
External earth cable
copyrighted
document
- all
rights
reserved
by
FBC