3.5. REMOVAL ONTO THE TENSIONING SYSTEM
3.5.1 Replacing the sensor assy
Step 1 :
Disconnect the power cable of the operation panel.
Step 2 :
Loosen the three screws fixing the cover of the tensioning sensor bracket.
Step 3 :
Remove the cover.
Step 4 :
Loosen the connectors.
Caution :
Be sure not to damage the cables nor the connectors.
Step 5 :
Loosen the two screws fixing the sensor bracket.