32
PGN
65531 (0xFFFB)
Source Address
224 (0xE0) Node offset of 0
PDU Format
255 (0xFF)
PDU Specific
251 (0xFB)
Built Message
(0x
18FFFBE0
)
Status Message 2 (Configuration and Output Status)
Name
Data Type
Byte
Bits
Description
Config Pair 1
2 Bit
1
1,2
Baud rate configuration jumper is applied
Config Pair 2
3,4
Node ID 1's configuration jumper is applied
Config Pair 3
5,6
Node ID 2's configuration jumper is applied
Config Pair 4
7,8
Node ID 3's configuration jumper is applied
Config Pair 5
2
1,2
Node ID 4's configuration jumper is applied
3,4
5,6
7,8
Output 1A Status
3
1,2
Status of Output 1A, (00 = off), (01 = on), (10 = fault)
Output 1B Status
3,4
Status of Output 1B, (00 = off), (01 = on), (10 = fault)
Output 2A Status
5,6
Status of Output 2A, (00 = off), (01 = on), (10 = fault)
Output 2B Status
7,8
Status of Output 2B, (00 = off), (01 = on), (10 = fault)
Output 3A Status
4
1,2
Status of Output 3A, (00 = off), (01 = on), (10 = fault)
Output 3B Status
3,4
Status of Output 3B, (00 = off), (01 = on), (10 = fault)
Output 4A Status
5,6
Status of Output 4A, (00 = off), (01 = on), (10 = fault)
Output 4B Status
7,8
Status of Output 4B, (00 = off), (01 = on), (10 = fault)
Output 5A Status
5
1,2
Status of Output 5A, (00 = off), (01 = on), (10 = fault)
Output 5B Status
3,4
Status of Output 5B, (00 = off), (01 = on), (10 = fault)
Output 6A Status
5,6
Status of Output 6A, (00 = off), (01 = on), (10 = fault)
Output 6B Status
7,8
Status of Output 6B, (00 = off), (01 = on), (10 = fault)
Output 7A Status
6
1,2
Status of Output 7A, (00 = off), (01 = on), (10 = fault)
Output 7B Status
3,4
Status of Output 7B, (00 = off), (01 = on), (10 = fault)
Output 8A Status
5,6
Status of Output 8A, (00 = off), (01 = on), (10 = fault)
Output 8B Status
7,8
Status of Output 8B, (00 = off), (01 = on), (10 = fault)
Power Buss P1
7
1,2
Status of Power Buss P1 (00 = off), (01 = on), (10 = fault)
Power Buss P2
3,4
Status of Power Buss P2 (00 = off), (01 = on), (10 = fault)
Power Buss P3
5,6
Status of Power Buss P3 (00 = off), (01 = on), (10 = fault)
Power Buss P4
7,8
Status of Power Buss P4 (00 = off), (01 = on), (10 = fault)
Save Config Counter
Byte
8
Count of how many times the configuration has been saved to the module
All source addresses are shown as module configured with no jumpers (Offset = 0)
Transmit rate
50 ms
Msg timeout
200 ms
Priority
6
DP
0