Status messages - Status message 1 PGN (EF(Controller Source Address)):
• Status 1 – Factory default configuration returns a value of 1, this should not be on if a module has been configured.
• Status 2 – Configuration Saved returns a value of 1 if the alternate configuration was on (value of 1) and saved the configuration
using “Save Configuration” in Command 52.
• Status 3 – Alternate configuration, a new configuration was made to the module but hasn’t been saved.
• Status 7, 9-13 – Returns a value of 1 each time a Command message 52-58 is sent, to ensure each configuration has been sent.
This is on for a brief moment and then resets.
Command 0x51(Outputs digital control and Inputs power control) and PWM control messages need to be consistently sent.
Please note PGNs are changing based on Node ID (node address), see section “PGNs USED” for details.
Configuration Sample Flowchart:
Configure Module
(Command 0 x 52)
Configure Outputs
(Command 0 x 53, 54)
Configure High Current Output Settings
(Command 0 x 58)
Save Configuration
(Command 0 x 52)
Check Status Message 1
(Software and Node Status)