34
PGN 5
65524 (0xFFF4)
Source Address
224 (0xE0) Node offset of 0
PDU Format
255 (0xFF)
PDU Specific
243 (0xF4)
Built Message
(0x
18FFF4E0
)
Status Message 5 (Output Amperage Feedback Port 5 -8)
Name
Data Type
Byte
Bits
Description
OUT 5A AMP FEEDBACK
Byte
1
Current reading on Port 5A, 0-4,000=0-4,000A
OUT 5B AMP FEEDBACK
2
Current reading on Port 5B, 0-4,000=0-4,000A
OUT 6A AMP FEEDBACK
3
Current reading on Port 6A, 0-4,000=0-4,000A
OUT 6B AMP FEEDBACK
4
Current reading on Port 6B, 0-4,000=0-4,000A
OUT 7A AMP FEEDBACK
5
Current reading on Port 7A, 0-4,000=0-4,000A
OUT 7B AMP FEEDBACK
6
Current reading on Port 7B, 0-4,000=0-4,000A
OUT 8A AMP FEEDBACK
7
Current reading on Port 8A, 0-4,000=0-4,000A
OUT 8B AMP FEEDBACK
8
Current reading on Port 8B, 0-4,000=0-4,000A
All addresses are shown as module configured with no jumpers (Offset = 0)
Transmit rate
50 ms
Msg timeout
200 ms
Priority
3
DP
0