Section 50
00-02-0674
04-16-10
-
18 -
5. Confirm that the MODBUS registers associated with the Remote have been reset to
zero. See the insert for a listing of these registers.
6. Reset Heartbeat Counters (
see page 13
).
How to Install a Battery in the Remote
IMPORTANT:
USE ONLY AUTHORIZED 3.6 VOLT LITHIUM BATTERIES.
NEVER MIX OLD AND NEW BATTERIES.
ALWAYS INSTALL A BATTERY IN THE CORRECT ORIENTATION.
The thermocouple remote requires two (2) batteries.
The discrete remote requires one (1) battery.
1. You must use an approved battery such as a Tadiran TL-5903-S which is available from
digikey.com.
2. Remove the PCB from the remote enclosure.
3. Remove the battery if one is installed.
4. In the event a battery was previously installed, press the switch for one second to drain
any residual energy stored on the Remote.
5. Insert the battery in the remote PCB assembly, while observing the battery polarity
between the battery clips in the PCB assembly.