Section 50
00-02-0674
04-16-10
-
15 -
7. Trim wires and strip ends approximately 9/32 inch
minimum.
8. Place wire ends in slot and screw down until snug.
NOTE:
Make sure wire connects directly to
the J301 terminal without looping the wire
inside casing.
9. Rotate the remote unit clockwise to 90° vertical
position.
10. Repeat steps 1-9 for each additional remote unit. Do
not replace lid until the remote has been activated
and is recognized by the Gateway.
NOTE:
The sensor resistance must be less than 25K Ohm. If the sensor
is greater than 25K Ohm, excessive current will reduce battery life.
11. Follow the
instructions for “Remote Activation”. Ensure the signal is recognized by the
Gateway before replacing the lid in the next step.
12. Replace the lid. Hand tighten all 4 screws, then tighten-to-snug in a cross pattern to
ensure even seating, as illustrated below.
IMPORTANT!
In order to meet NEMA 4 requirements, ensure all 4
screws are used to hold the lid in place.