![Munters TRIO User And Installation Manual Download Page 140](http://html.mh-extra.com/html/munters/trio/trio_user-and-installation-manual_1856900140.webp)
© Munters AB, 2020
140
14.2
Zone Heaters
Define relays and/or analogue output ports as heaters in Mapping Devices, page 50.
Define at least one heater as a Zone Heater in Heating Devices, page 65.
•
Defining Non-Variable Zone Heaters
•
Defining Variable Zone Heaters
14.2.1
D
EFINING
N
ON
-V
ARIABLE
Z
ONE
H
EATERS
1. Go to Climate > Zone Heaters.
2. Click
.
3. Define:
o
On Temp Diff: This is a differential. When the temperature reaches the target temperature
minus this amount, heating begins.
o
Off Temp Diff. This is a differential. When the temperature reaches the target temperature
minus this amount, heating stops.
14.2.2
D
EFINING
V
ARIABLE
Z
ONE
H
EATERS
1. Go to Climate > Zone Heaters.
2. Click
.
3. Define:
o
On Temp Diff: This is a differential. When the temperature reaches the target temperature
minus this amount, heating begins.
Summary of Contents for TRIO
Page 18: ... Munters AB 2020 18 Figure 5 Relay wiring detailed view Figure 6 Relay and port numbering ...
Page 86: ... Munters AB 2020 86 ...
Page 88: ... Munters AB 2020 88 4 Verify that each channel is enabled ...
Page 170: ... Munters AB 2020 170 Click to view the bird scale data ...
Page 180: ... Munters AB 2020 180 25 3 2TRIO 20 CONTAINER SPARE PARTS ...
Page 182: ... Munters AB 2020 182 25 3 3TRIO 20 DOOR CARD SPARE PARTS ...
Page 184: ... Munters AB 2020 184 25 3 4TRIO 20 MAIN CONTAINER SPARE PARTS ...
Page 196: ... Munters AB 2020 196 Figure 36 Relay and port numbering 26 2 3POWER Figure 37 Power ports ...