© Munters AB, 2020
140
14.2
Zone Heaters
Define relays and/or analogue output ports as heaters in Mapping Devices, page 50.
Define at least one heater as a Zone Heater in Heating Devices, page 65.
•
Defining Non-Variable Zone Heaters
•
Defining Variable Zone Heaters
14.2.1
D
EFINING
N
ON
-V
ARIABLE
Z
ONE
H
EATERS
1. Go to Climate > Zone Heaters.
2. Click
.
3. Define:
o
On Temp Diff: This is a differential. When the temperature reaches the target temperature
minus this amount, heating begins.
o
Off Temp Diff. This is a differential. When the temperature reaches the target temperature
minus this amount, heating stops.
14.2.2
D
EFINING
V
ARIABLE
Z
ONE
H
EATERS
1. Go to Climate > Zone Heaters.
2. Click
.
3. Define:
o
On Temp Diff: This is a differential. When the temperature reaches the target temperature
minus this amount, heating begins.