![Munters TRIO User And Installation Manual Download Page 104](http://html.mh-extra.com/html/munters/trio/trio_user-and-installation-manual_1856900104.webp)
© Munters AB, 2020
104
9.2.2
D
EFINING
T
EMPERATURE
C
URVE
S
ETTINGS
1. Click
.
2. Define:
o
Target Offset: Adjusts all temperature curves by this amount. You can use this to
temporarily adjust all temperatures up or down for special circumstances. The offset
applies to all table parameters.
o
Sensor Low T° Below Alarm: Set value below which the “Low temperature sensor” alarm
is activated. This is a differential. Range 0.0° - 10.0°
o
Sensor High T° Above Alarm Diff: Set value above which the “High temperature sensor”
alarm is activated. This is a differential. Range 0.0° - 10.0°
o
Outside Temperature Compensation: High temperature set point = measured outside
tempe “outside temperature compensation”. Range [0.0° – 10.0°]
o
Absolute High Temperature: Set the critical temperature (maximum allowable).
9.3
Emergency Temperature Control
In the event that TRIO fails to receive a signal from the temperature sensor for an extended period of time,
an alarm is triggered. Between the time that TRIO stops receiving a signal and when an alarm is
triggered, ventilation remains at the current level. When an alarm is triggered:
•
If there is an outside temperature sensor,
o
ventilation is adjusted.
o
Ventilation levels will not fall lower than the Minimum Ventilation
•
If there is no outside temperature sensor
o
maintain the last known positive output (before the failure)
o
turn off negative output
o
Cooling and air quality treatment cease
Summary of Contents for TRIO
Page 18: ... Munters AB 2020 18 Figure 5 Relay wiring detailed view Figure 6 Relay and port numbering ...
Page 86: ... Munters AB 2020 86 ...
Page 88: ... Munters AB 2020 88 4 Verify that each channel is enabled ...
Page 170: ... Munters AB 2020 170 Click to view the bird scale data ...
Page 180: ... Munters AB 2020 180 25 3 2TRIO 20 CONTAINER SPARE PARTS ...
Page 182: ... Munters AB 2020 182 25 3 3TRIO 20 DOOR CARD SPARE PARTS ...
Page 184: ... Munters AB 2020 184 25 3 4TRIO 20 MAIN CONTAINER SPARE PARTS ...
Page 196: ... Munters AB 2020 196 Figure 36 Relay and port numbering 26 2 3POWER Figure 37 Power ports ...