Troubleshooting
7.
Fan Operating-
Insu
ffi
cient
Air
fl
ow
Excessive
Vibration
Excessive Noise
1. Fan control set above room
temperature
2. Blown fuse or open circuit breaker
3. Propeller blade contacting fan
housing
4. Fan control defective
1. Shutter jammed or dirty
2. Guard dirty
3. Frequency drive improperly adjusted
4. Incorrect Belt Tension/worn belt
1. Propeller blade contacting fan housing
2. Motor bearing or shaft bearing defective
3. Frequency drive improperly adjusted
1. Motor loose on mount
2. Propeller damaged
1. Set to a lower temperature
2. Replace fuse or reset breaker
3. Realign motor in fan housing
4. Repair or replace control
5. Repair or replace motor
1. Unjam and clean shutter
2. Clean guard
3. See operation, Step 2 for adjustments guidelines
4. See Maintenance Section, Belt Tensioning
1. Sand fan housing to remove high spot
2. Repair or replace motor or shaft bearings
3. See operation, Step 2 for adjustments guidelines
1. Tighten fasteners
2. Replace propeller
3. Repair or replace motor or propeller shaft
Fan Not Operating
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE ACTION
7.1 Troubleshooting
WARNING
!
High Voltage, disconnect
power before servicing.
WARNING
!
Moving parts, disconnect
power before servicing.
WARNING
!
Moving parts, disconnect
power before servicing.