No.
Name
CN#
Meaning
1
Power Supply
CN6
Earth: connect to Ground
CN7
N_in: connect to N-line (208-230V AC input)
CN8
L_in: connect to L-line (208-230V AC input)
2
S
CN2
S: connect to indoor unit communication
3
4-WAY
CN60
connect to 4 way valve, 208-230V AC when is ON.
4
AC-FAN
CN5
connect to AC fan
5
HEAT2
CN19
connect to chassis heater, 208-230V AC when is ON
6
TP T4 T3
CN17
connect to pipe temp. sensor T3, ambient temp. sensor T4, exhaust
temp. sensor TP
7
PMV
CN18
connect to Electric Expansion Valve
8
HEAT1
CN16
connect to compressor heater, 208-230V AC when is ON
9
DC-FAN
CN414
connect to DC fan
10
TESTPORT
CN23
used for testing
11
FAN_IPM
IPM501
IPM for DC fan
12
COMP_IPM
IPM1
IPM for compressor
13
U
CN27
connect to compressor
V
CN28
0V AC (standby)
W
CN29
200-300V AC (running)
14
EE_PORT
CN505
EEPROM programer port
Note: This section is for reference only. Please take practicality as standard.
Service manual
H11 series
Specifications 13
f
e
Summary of Contents for MUPR-09-H11-E
Page 1: ...Service manual MUPR H11 www mundoclima com CL20055 CL20058 R32...
Page 16: ...Service manual H11 series MUPR 24 H11 I Specifications 7f e...
Page 18: ...Service manual H11 series MUPR 24 H11 E Specifications 9 f e...
Page 59: ...e Outdoor Unit Disassembly 4 f 2 Panel Plate X301 Service manual H11 series MUPR 18 H11 E...
Page 60: ...e Outdoor Unit Disassembly 5 f 3 Panel Plate X401 Service manual H11 series MUPR 24 H11 E...
Page 117: ...Service manual H11 series e f Troubleshooting 25...