![mundoclima MUPR-09-H11-E Service Manual Download Page 99](http://html1.mh-extra.com/html/mundoclima/mupr-09-h11-e/mupr-09-h11-e_service-manual_1856741099.webp)
e
Troubleshooting 7
f
Parameter Checking information by Remote controller
Displaying code
Displaying code meaning
Display value
Display value meaning
T1
Room temperature
T2
Indoor coil temperature
T3
Outdoor coil temperature
T4
Ambient temperature
TP
Discharge temperature
FT
Targeted Frequency
Fr
Actual Frequency
dl
Compressor current
Uo
Outdoor AC voltage
Sn
Indoor capacity test
--
Reserve
Pr
Outdoor fan speed
Lr
EXV opening steps
ir
Indoor fan speed
HU
Indoor humidity
TT
Adjusted setting temperature
--
Reserve
--
Reserve
oT
GA algorithm frequency
Approval from Manufacturer
□
Approved
□
More Proof needed
□
Rejected
Service manual
H11 series
Summary of Contents for MUPR-09-H11-E
Page 1: ...Service manual MUPR H11 www mundoclima com CL20055 CL20058 R32...
Page 16: ...Service manual H11 series MUPR 24 H11 I Specifications 7f e...
Page 18: ...Service manual H11 series MUPR 24 H11 E Specifications 9 f e...
Page 59: ...e Outdoor Unit Disassembly 4 f 2 Panel Plate X301 Service manual H11 series MUPR 18 H11 E...
Page 60: ...e Outdoor Unit Disassembly 5 f 3 Panel Plate X401 Service manual H11 series MUPR 24 H11 E...
Page 117: ...Service manual H11 series e f Troubleshooting 25...