![Multiva Cerex 300 Comfort Operation And Maintenance Manual Download Page 176](http://html1.mh-extra.com/html/multiva/cerex-300-comfort/cerex-300-comfort_operation-and-maintenance-manual_1856359176.webp)
The machine cannot
be lifted
1. The lift
inhibit function
is enabled
1. Disable the lift inhibit function in accordance
with section 6.3.1. Active operating mode.
2. Machine
lifting circuit
ball valve is
closed
2. Open the machine lifting circuit ball valve in
accordance with section 5.3.5. Using the machine
3. The quick
coupling is
open
3. Check the connection of the quick-release
coupling.
The machine cannot
be lowered
1. Machine
lifting circuit
ball valve is
closed
1. Open the machine lifting circuit ball valve in
accordance with section 5.3.5. Using the machine
2. The quick
coupling is
open
2. Check the connection of the quick-release
coupling.
3. The stoppers
are in place in
the lifting
cylinder
3. Remove the stoppers from the lifting cylinder.
Hopper alarm does
not function
1. The alarm
has been
disabled
1. Enable the alarm from the settings in accordance
with section 4.2.4.1. User setup.
The axle rotation
guard does not
function
1. The alarm
has been
disabled
1. Enable the alarm from the settings in accordance
with section 4.2.4.1. User setup.
Operation and maintenance manual
Cerex 300 and Cerex 400 Comfort
1.00
176 (187)
Summary of Contents for Cerex 300 Comfort
Page 179: ...Hydraulic schematics Cerex 300 and Cerex 400 1 Hydraulic schematics Cerex 300...
Page 180: ...Hydraulic schematics Cerex 300 and Cerex 400 2...
Page 181: ...Hydraulic schematics Cerex 300 and Cerex 400 3 Hydraulic schematics Cerex 400...
Page 182: ...Hydraulic schematics Cerex 300 and Cerex 400 4...
Page 183: ...Electrical schematics Cerex 300 and Cerex 400 Comfort 1 Electrical schematics...
Page 184: ...Electrical schematics Cerex 300 and Cerex 400 Comfort 2...
Page 185: ...Electrical schematics Cerex 300 and Cerex 400 Comfort 3...